ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0614 # 05 Y:2012 | 05 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,500 | $5,370 | Implemented |
AM0614 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $500 | $280 | Not Implemented |
AM0614 # 01 Y:2012 | 01 | 2012 | OPTIMIZE PLANT POWER FACTOR | $12,400 | $24,400 | Implemented |
AM0614 # 02 Y:2012 | 02 | 2012 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $51,500 | $1,500 | Implemented |
AM0614 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,300 | $15 | Implemented |
AM0614 # 06 Y:2012 | 06 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $700 | $780 | Implemented |
AM0614 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,800 | $700 | Implemented |
AM0614 # 07 Y:2012 | 07 | 2012 | USE SYNTHETIC LUBRICANT | $490 | $0 | Implemented |
AM0614 # 09 Y:2012 | 09 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $30 | $630 | Not Implemented |
AM0469 # 07 Y:2004 | 07 | 2004 | USE SYNTHETIC LUBRICANT | $260 | $0 | Not Implemented |
AM0469 # 06 Y:2004 | 06 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $340 | $0 | Implemented |
AM0469 # 05 Y:2004 | 05 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $890 | $0 | Not Implemented |
AM0469 # 04 Y:2004 | 04 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,460 | $170 | Implemented |
AM0469 # 01 Y:2004 | 01 | 2004 | CONVERT TO ELECTROSTATIC POWDER COATING | $934,000 | $500,000 | Not Implemented |
AM0469 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,900 | $400 | Implemented |
AM0469 # 03 Y:2004 | 03 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,000 | $0 | Implemented |
AM0457 # 08 Y:2004 | 08 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,910 | $880 | Implemented |
AM0457 # 07 Y:2004 | 07 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $84,400 | $8,800 | Not Implemented |
AM0457 # 06 Y:2004 | 06 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $230 | $0 | Implemented |
AM0457 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $265 | $130 | Implemented |
AM0457 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $790 | $500 | Implemented |
AM0457 # 03 Y:2004 | 03 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,270 | $120 | Implemented |
AM0457 # 02 Y:2004 | 02 | 2004 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,360 | $4,370 | Implemented |
AM0457 # 01 Y:2004 | 01 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,750 | $21 | Implemented |
AM0358 # 02 Y:1999 | 02 | 1999 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,680 | $80 | Implemented |