Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

40

matching recommendations
Reset
SIC 3443 Fabricated Plate Work (boiler Shops)
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0326 # 08 Y:2003 08 2003 INSTALL TIMERS AND/OR THERMOSTATS $2,034 $500 Not Implemented
SD0326 # 07 Y:2003 07 2003 USE PHOTOCELL CONTROLS $4,846 $6,000 Not Implemented
SD0326 # 04 Y:2003 04 2003 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $14,893 $7,700 Not Implemented
SD0326 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $35,397 $4,000 Implemented
SD0326 # 06 Y:2003 06 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $4,905 $7,000 Not Implemented
SD0326 # 03 Y:2003 03 2003 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $15,861 $20,000 Not Implemented
SD0326 # 05 Y:2003 05 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,795 $384 Not Implemented
SD0326 # 01 Y:2003 01 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $44,623 $0 Not Implemented
SD0220 # 07 Y:1999 07 1999 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS $51,493 $8,000 Implemented
SD0220 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,040 $5,528 Implemented
SD0220 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,440 $500 Implemented
SD0220 # 03 Y:1999 03 1999 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $55,972 $80,000 Not Implemented
SD0220 # 05 Y:1999 05 1999 CONVERT TO AQUEOUS CLEANING $7,548 $0 Implemented
SD0220 # 06 Y:1999 06 1999 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $7,710 $8,500 Implemented
SD0220 # 04 Y:1999 04 1999 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $17,838 $732 Implemented
SD0191 # 01 Y:1998 01 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,838 $5,890 Implemented
SD0191 # 02 Y:1998 02 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $45,498 $34,650 Not Implemented
SD0191 # 03 Y:1998 03 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,897 $1,800 Not Implemented
SD0191 # 04 Y:1998 04 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,084 $41,850 Not Implemented
SD0191 # 05 Y:1998 05 1998 USE OPTIMUM THICKNESS INSULATION $3,919 $5,418 Not Implemented
SD0191 # 06 Y:1998 06 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $18,900 $8,500 Implemented
SD0191 # 07 Y:1998 07 1998 CONVERT TO LESS TOXIC HYDROCARBON CLEANERS $15,696 $1,450 Not Implemented
SD0191 # 08 Y:1998 08 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $12,650 $0 Implemented
SD0191 # 09 Y:1998 09 1998 TREAT AND REUSE RINSE WATERS $654 $750 Implemented
SD0191 # 10 Y:1998 10 1998 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $28,755 $200,000 Not Implemented