Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,512
matching recommendationsSIC | 3444 | Sheet Metalwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0193 # 04 Y:2000 | 04 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,402 | $5,673 | Not Implemented |
SF0193 # 05 Y:2000 | 05 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,316 | $6,961 | Not Implemented |
SF0193 # 06 Y:2000 | 06 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,201 | $9,000 | Implemented |
SF0193 # 07 Y:2000 | 07 | 2000 | USE ALTERNATIVE FLOCCULENT TO MINIMIZE SLUDGE VOLUME | $8,950 | $16,000 | Not Implemented |
SD0249 # 01 Y:2000 | 01 | 2000 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $12,372 | $25 | Implemented |
SD0249 # 02 Y:2000 | 02 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $898 | $600 | Implemented |
SD0249 # 03 Y:2000 | 03 | 2000 | AUTOMATE FINISHING PROCESS | $62,250 | $100,000 | Not Implemented |
SD0249 # 04 Y:2000 | 04 | 2000 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $25,500 | $23,000 | Not Implemented |
AM0374 # 01 Y:2000 | 01 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,510 | $350 | Not Implemented |
AM0374 # 02 Y:2000 | 02 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,670 | $910 | Not Implemented |
AM0374 # 03 Y:2000 | 03 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,080 | $0 | Not Implemented |
AM0374 # 04 Y:2000 | 04 | 2000 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,010 | $610 | Implemented |
AM0374 # 05 Y:2000 | 05 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $930 | $78 | Implemented |
AM0374 # 06 Y:2000 | 06 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $470 | $155 | Implemented |
SD0247 # 01 Y:2000 | 01 | 2000 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $11,396 | $8,250 | Not Implemented |
SD0247 # 02 Y:2000 | 02 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,905 | $3,000 | Not Implemented |
SD0247 # 03 Y:2000 | 03 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,007 | $0 | Not Implemented |
SD0247 # 04 Y:2000 | 04 | 2000 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $5,628 | $3,000 | Not Implemented |
SD0247 # 05 Y:2000 | 05 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,279 | $1,800 | Not Implemented |
SD0247 # 06 Y:2000 | 06 | 2000 | INSULATE BARE EQUIPMENT | $570 | $1,030 | Not Implemented |
SD0247 # 07 Y:2000 | 07 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,440 | $12,500 | Not Implemented |
SD0247 # 08 Y:2000 | 08 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $6,916 | $0 | Not Implemented |
SD0247 # 09 Y:2000 | 09 | 2000 | IMPROVE SPACE COMFORT CONDITIONING | $32,000 | $10,380 | Not Implemented |
SD0242 # 01 Y:2000 | 01 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $14,399 | $1,960 | Implemented |
SD0242 # 02 Y:2000 | 02 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,283 | $3,000 | Not Implemented |