Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,512
matching recommendationsSIC | 3444 | Sheet Metalwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0322 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $3,399 | $5,800 | Not Implemented |
OR0322 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,116 | $1,000 | Not Implemented |
OR0319 # 01 Y:1998 | 01 | 1998 | ELIMINATE SHIFT | $200,000 | $2,500 | Implemented |
OR0319 # 02 Y:1998 | 02 | 1998 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $32,660 | $300,000 | Implemented |
OR0319 # 03 Y:1998 | 03 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $31,569 | $931 | Implemented |
OR0319 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $833 | $1,000 | Implemented |
OR0319 # 05 Y:1998 | 05 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $355 | $1,750 | Implemented |
WI0324 # 01 Y:1998 | 01 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,936 | $0 | Not Implemented |
WI0324 # 02 Y:1998 | 02 | 1998 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $487 | $0 | Implemented |
WI0324 # 03 Y:1998 | 03 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,780 | $850 | Not Implemented |
WI0324 # 04 Y:1998 | 04 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,054 | $400 | Implemented |
WI0324 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $381 | $90 | Implemented |
WI0324 # 06 Y:1998 | 06 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $372 | $640 | Implemented |
WI0324 # 07 Y:1998 | 07 | 1998 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,039 | $0 | Not Implemented |
WI0319 # 01 Y:1998 | 01 | 1998 | INSTALL SENSORS TO DETECT DEFECTS | $69,212 | $63,760 | Not Implemented |
WI0319 # 02 Y:1998 | 02 | 1998 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $6,046 | $13,200 | Not Implemented |
WI0319 # 03 Y:1998 | 03 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,599 | $18,400 | Not Implemented |
WI0319 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,295 | $940 | Not Implemented |
WI0319 # 05 Y:1998 | 05 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,187 | $500 | Not Implemented |
WI0319 # 06 Y:1998 | 06 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $214 | $0 | Implemented |
AS0219 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,150 | $2,888 | Implemented |
AS0219 # 02 Y:1998 | 02 | 1998 | USE SYNTHETIC LUBRICANT | $101 | $268 | Implemented |
AS0219 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,071 | $60 | Implemented |
AS0219 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,138 | $2,957 | Implemented |
AS0219 # 05 Y:1998 | 05 | 1998 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,425 | $1,500 | Implemented |