Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

376

matching recommendations
Reset
SIC 3448 Prefabricated Metal Buildings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0547 # 01 Y:1995 01 1995 INSTALL TIMERS AND/OR THERMOSTATS $8,342 $5,800 Implemented
TN0508 # 05 Y:1994 05 1994 OPTIMIZE PLANT POWER FACTOR $33,000 $15,800 Not Implemented
TN0508 # 04 Y:1994 04 1994 USE DEMAND CONTROLLER OR LOAD SHEDDER $4,849 $240 Implemented
TN0508 # 03 Y:1994 03 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $199 $250 Not Implemented
TN0508 # 02 Y:1994 02 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $1,160 $0 Implemented
TN0508 # 01 Y:1994 01 1994 USE SYNTHETIC LUBRICANT $1,313 $0 Not Implemented
NC0004 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,514 $1,222 Implemented
NC0004 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,054 $690 Implemented
NC0004 # 03 Y:1993 03 1993 RECOVER AND REUSE COOLING WATER $834 $500 Not Implemented
NC0004 # 04 Y:1993 04 1993 RECOVER WASTE HEAT FROM EQUIPMENT $26,384 $1,500 Not Implemented
NC0004 # 05 Y:1993 05 1993 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,143 $1,100 Not Implemented
NC0004 # 06 Y:1993 06 1993 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,494 $4,500 Not Implemented
AM0179 # 01 Y:1993 01 1993 OPTIMIZE PLANT POWER FACTOR $34,850 $45,000 Implemented
AM0179 # 02 Y:1993 02 1993 USE RADIANT HEATER FOR SPOT HEATING $14,970 $10,890 Not Implemented
AM0179 # 03 Y:1993 03 1993 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $10,850 $0 Implemented
AM0179 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,280 $500 Implemented
AM0179 # 05 Y:1993 05 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,640 $0 Not Implemented
AM0179 # 06 Y:1993 06 1993 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,210 $1,230 Not Implemented
AM0179 # 07 Y:1993 07 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $760 $3,920 Not Implemented
IA0034 # 01 Y:1992 01 1992 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,906 $17,000 Not Implemented
IA0034 # 02 Y:1992 02 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,216 $240 Implemented
IA0034 # 03 Y:1992 03 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,355 $200 Not Implemented
IA0034 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $585 $83 Not Implemented
IA0034 # 05 Y:1992 05 1992 INSTALL SET-BACK TIMERS $594 $1,170 Not Implemented
IA0034 # 06 Y:1992 06 1992 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $352 $100 Implemented