Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

51

matching recommendations
Reset
SIC 3448 Prefabricated Metal Buildings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0192 # 09 Y:2001 09 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,939 $5,000 Not Implemented
BD0192 # 08 Y:2001 08 2001 INSTALL TURBULATORS $8,641 $1,500 Not Implemented
BD0192 # 07 Y:2001 07 2001 USE SYNTHETIC LUBRICANT $9,075 $5,000 Not Implemented
BD0192 # 06 Y:2001 06 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $11,555 $24,950 Implemented
BD0192 # 05 Y:2001 05 2001 DIRECT WARMEST AIR TO COMBUSTION INTAKE $12,605 $35,000 Not Implemented
BD0192 # 04 Y:2001 04 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20,184 $51,960 Not Implemented
BD0192 # 03 Y:2001 03 2001 DISCONNECT BALLASTS $27,741 $12,400 n/a
BD0192 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $36,965 $4,300 Not Implemented
BD0192 # 01 Y:2001 01 2001 USE RADIANT HEATER FOR SPOT HEATING $276,125 $40,500 Not Implemented
BD0153 # 05 Y:2000 05 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $245 $235 Not Implemented
BD0153 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,555 $13,420 Implemented
BD0153 # 02 Y:2000 02 2000 INSTALL OCCUPANCY SENSORS $3,918 $930 Implemented
BD0153 # 03 Y:2000 03 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,648 $1,125 Implemented
BD0153 # 04 Y:2000 04 2000 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $826 $0 Implemented
BD0153 # 06 Y:2000 06 2000 USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE $1,494 $4,825 Not Implemented
BD0153 # 07 Y:2000 07 2000 MODIFY MATERIAL APPLICATION METHODS $1,171 $1,500 Implemented
BD0153 # 08 Y:2000 08 2000 AUTOMATE PAYROLL SYSTEM $7,644 $7,000 Not Implemented
BD0122 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,044 $12,900 Not Implemented
BD0122 # 09 Y:1998 09 1998 PAY BILLS ON TIME TO AVOID LATE FEES $313 $0 Implemented
BD0122 # 08 Y:1998 08 1998 AUTOMATE FINISHING PROCESS $12,828 $25,000 Not Implemented
BD0122 # 07 Y:1998 07 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $8,070 $8,000 Not Implemented
BD0122 # 06 Y:1998 06 1998 INSULATE FEEDWATER TANK $56,279 $15,800 Not Implemented
BD0122 # 05 Y:1998 05 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $351 $250 Implemented
BD0122 # 04 Y:1998 04 1998 RECOVER WASTE HEAT FROM EQUIPMENT $1,934 $750 Implemented
BD0122 # 03 Y:1998 03 1998 INSTALL OCCUPANCY SENSORS $2,196 $1,350 Not Implemented