Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

376

matching recommendations
Reset
SIC 3448 Prefabricated Metal Buildings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0386 # 05 Y:2006 05 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,134 $2,420 Not Implemented
IA0386 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $384 $706 Not Implemented
IA0386 # 03 Y:2006 03 2006 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,908 $4 Implemented
IA0386 # 02 Y:2006 02 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,621 $15 Implemented
IA0386 # 01 Y:2006 01 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,747 $276 Implemented
MS0286 # 01 Y:2005 01 2005 AIR CONDITION ONLY SPACE NECESSARY $6,625 $0 Not Implemented
IA0362 # 11 Y:2005 11 2005 PAY BILLS ON TIME TO AVOID LATE FEES $1,000 $0 Not Implemented
IA0362 # 10 Y:2005 10 2005 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $6,630 $2,280 Not Implemented
IA0362 # 09 Y:2005 09 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $352 $471 Implemented
IA0362 # 08 Y:2005 08 2005 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $6,630 $0 Not Implemented
IA0362 # 07 Y:2005 07 2005 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $791 $350 Not Implemented
IA0362 # 06 Y:2005 06 2005 INSTALL OCCUPANCY SENSORS $511 $1,309 Not Implemented
IA0362 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $429 $502 Implemented
IA0362 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,552 $3,000 Implemented
IA0362 # 03 Y:2005 03 2005 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $845 $207 Not Implemented
IA0362 # 02 Y:2005 02 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,270 $1,000 Implemented
IA0362 # 01 Y:2005 01 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $385 $30 Not Implemented
AM0462 # 01 Y:2004 01 2004 PAY UTILITY BILLS ON TIME $26,800 $6,700 Implemented
AM0462 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,320 $2,000 Implemented
AM0462 # 03 Y:2004 03 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,200 $1,400 Implemented
AM0462 # 04 Y:2004 04 2004 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $3,060 $0 Implemented
AM0462 # 05 Y:2004 05 2004 INSTALL SKYLIGHTS $2,670 $6,600 Not Implemented
AM0462 # 06 Y:2004 06 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,630 $45 Not Implemented
AM0462 # 07 Y:2004 07 2004 INSTALL SKYLIGHTS $1,330 $2,500 Implemented
AM0462 # 08 Y:2004 08 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,050 $770 Implemented