Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
202
matching recommendationsSIC | 3449 | Miscellaneous Metal Work |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0500 # 08 Y:2013 | 08 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,461 | $210 | Implemented |
IA0500 # 09 Y:2013 | 09 | 2013 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $280 | $110 | Not Implemented |
IA0500 # 10 Y:2013 | 10 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,264 | $15,781 | Implemented |
IA0500 # 11 Y:2013 | 11 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,837 | $16,072 | Implemented |
IP0002 # 08 Y:2012 | 08 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $760 | $1,216 | Not Implemented |
IP0002 # 07 Y:2012 | 07 | 2012 | INSULATE BARE EQUIPMENT | $1,205 | $1,430 | Not Implemented |
IP0002 # 06 Y:2012 | 06 | 2012 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $5,124 | $4,678 | Implemented |
IP0002 # 05 Y:2012 | 05 | 2012 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $2,700 | $1,250 | Not Implemented |
IP0002 # 04 Y:2012 | 04 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,900 | $1,320 | Implemented |
IP0002 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,515 | $140 | Implemented |
IP0002 # 02 Y:2012 | 02 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,887 | $0 | Not Implemented |
IP0002 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $18,621 | $0 | Implemented |
TA0125 # 03 Y:2006 | 03 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $268,990 | $0 | Implemented |
TA0125 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $894 | $0 | Implemented |
TA0125 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,191 | $155 | Implemented |
TA0125 # 04 Y:2006 | 04 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $421 | $0 | Implemented |
TA0124 # 03 Y:2006 | 03 | 2006 | INSTALL OCCUPANCY SENSORS | $90 | $135 | Implemented |
TA0124 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,410 | $625 | Implemented |
TA0124 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,256 | $0 | Implemented |
TA0124 # 04 Y:2006 | 04 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $20,890 | $0 | Implemented |
TA0124 # 05 Y:2006 | 05 | 2006 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,050 | $6,882 | Not Implemented |
TA0124 # 06 Y:2006 | 06 | 2006 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,664 | $832 | Implemented |
TA0121 # 03 Y:2006 | 03 | 2006 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,838 | $2,419 | Not Implemented |
TA0121 # 04 Y:2006 | 04 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,770 | $1,770 | Not Implemented |
TA0121 # 02 Y:2006 | 02 | 2006 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $160 | $300 | Not Implemented |