Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
437
matching recommendationsSIC | 345 | Screw Machine Products, Bolts, Etc. |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
HO0008 # 02 Y:1991 | 02 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,973 | $742 | Implemented |
HO0008 # 03 Y:1991 | 03 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,555 | $0 | Implemented |
HO0008 # 04 Y:1991 | 04 | 1991 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $235,098 | $0 | Implemented |
RU0109 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,147 | $0 | Implemented |
RU0109 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,160 | $308 | Implemented |
RU0109 # 03 Y:1991 | 03 | 1991 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,849 | $2,500 | Implemented |
RU0109 # 04 Y:1991 | 04 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $851 | $300 | Implemented |
RU0109 # 05 Y:1991 | 05 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,456 | $0 | Implemented |
RU0109 # 06 Y:1991 | 06 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,570 | $166 | Implemented |
RU0109 # 07 Y:1991 | 07 | 1991 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $88 | $28 | Implemented |
RU0109 # 08 Y:1991 | 08 | 1991 | INSTALL / REPAIR INSULATION ON STEAM LINES | $374 | $180 | Implemented |
RU0109 # 09 Y:1991 | 09 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $509 | $500 | Implemented |
RU0109 # 10 Y:1991 | 10 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,121 | $0 | Implemented |
RU0113 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,496 | $0 | Implemented |
RU0113 # 02 Y:1991 | 02 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,138 | $330 | Implemented |
RU0113 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,196 | $1,735 | Implemented |
RU0113 # 04 Y:1991 | 04 | 1991 | COVER OPEN TANKS | $506 | $1,164 | Implemented |
RU0113 # 05 Y:1991 | 05 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,454 | $0 | Implemented |
RU0113 # 06 Y:1991 | 06 | 1991 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $17,916 | $11,500 | Implemented |
RU0113 # 07 Y:1991 | 07 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,091 | $500 | Implemented |
RU0113 # 08 Y:1991 | 08 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,756 | $6,800 | Implemented |
WI0108 # 01 Y:1991 | 01 | 1991 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,400 | $10,000 | Implemented |
WI0108 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $893 | $232 | Implemented |
WI0108 # 03 Y:1991 | 03 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,190 | $400 | Implemented |
WI0108 # 04 Y:1991 | 04 | 1991 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $487 | $250 | Implemented |