IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

33

matching recommendations
Reset
SIC 345 Screw Machine Products, Bolts, Etc.
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0196 # 11 Y:2001 11 2001 PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW $6,140 $1,000 Not Implemented
BD0196 # 10 Y:2001 10 2001 ELIMINATE LEAKS IN WATER LINES AND VALVES $2,862 $750 Implemented
BD0196 # 09 Y:2001 09 2001 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $5,282 $7,000 Not Implemented
BD0196 # 08 Y:2001 08 2001 USE EVAPORATION TO CONCENTRATE MATERIAL $19,775 $27,000 Not Implemented
BD0196 # 07 Y:2001 07 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $754 $1,260 Not Implemented
BD0196 # 06 Y:2001 06 2001 INSTALL OCCUPANCY SENSORS $984 $1,725 Implemented
BD0196 # 05 Y:2001 05 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,004 $3,780 Not Implemented
BD0196 # 04 Y:2001 04 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,477 $200 Implemented
BD0196 # 03 Y:2001 03 2001 USE SYNTHETIC LUBRICANT $1,892 $900 Not Implemented
BD0196 # 02 Y:2001 02 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,026 $2,250 Not Implemented
BD0196 # 01 Y:2001 01 2001 USE RADIANT HEATER FOR SPOT HEATING $41,697 $18,000 Not Implemented
MA0492 # 02 Y:2001 02 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,800 $360 Implemented
MA0492 # 05 Y:2001 05 2001 INSTALL OCCUPANCY SENSORS $480 $200 Implemented
MA0492 # 04 Y:2001 04 2001 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,160 $12,000 Not Implemented
MA0492 # 03 Y:2001 03 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,800 $15,000 Not Implemented
MA0492 # 01 Y:2001 01 2001 USE EVAPORATION TO CONCENTRATE MATERIAL $23,000 $10,000 Not Implemented
MA0490 # 06 Y:2001 06 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,100 $1,000 Implemented
MA0490 # 01 Y:2001 01 2001 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $7,248 $0 Implemented
MA0490 # 07 Y:2001 07 2001 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,000 $0 Implemented
MA0490 # 02 Y:2001 02 2001 RECOVER WASTE HEAT FROM EQUIPMENT $6,500 $14,500 Not Implemented
MA0490 # 04 Y:2001 04 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,350 $5,000 Not Implemented
MA0490 # 05 Y:2001 05 2001 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $1,500 $6,000 Not Implemented
MA0490 # 03 Y:2001 03 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,500 $390 Implemented
AM0398 # 08 Y:2001 08 2001 PAY UTILITY BILLS ON TIME $295 $0 Implemented
AM0398 # 07 Y:2001 07 2001 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $310 $0 Implemented