Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

175

matching recommendations
Reset
SIC 3451 Screw Machine Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0088 # 10 Y:1993 10 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,254 $0 Implemented
AS0088 # 12 Y:1993 12 1993 INSTALL TIMERS AND/OR THERMOSTATS $1,022 $1,120 Implemented
WI0174 # 02 Y:1993 02 1993 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $1,898 $0 Implemented
HO0008 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $631 $1,032 Implemented
HO0008 # 02 Y:1991 02 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,973 $742 Implemented
HO0008 # 03 Y:1991 03 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,555 $0 Implemented
HO0008 # 04 Y:1991 04 1991 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $235,098 $0 Implemented
WI0099 # 01 Y:1990 01 1990 IMPROVE LUBRICATION PRACTICES $6,079 $0 Implemented
WI0099 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,874 $6,425 Implemented
WI0099 # 07 Y:1990 07 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,255 $1,000 Implemented
WI0099 # 08 Y:1990 08 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,027 $0 Implemented
WI0099 # 10 Y:1990 10 1990 INSTALL TIMERS AND/OR THERMOSTATS $1,991 $520 Implemented
CO0167 # 01 Y:1989 01 1989 OPTIMIZE PLANT POWER FACTOR $6,740 $6,800 Implemented
CO0167 # 02 Y:1989 02 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,010 $150 Implemented
CO0167 # 06 Y:1989 06 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $455 $335 Implemented
CO0167 # 07 Y:1989 07 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $105 $315 Implemented
CO0167 # 08 Y:1989 08 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $870 $200 Implemented
CO0167 # 09 Y:1989 09 1989 INSULATE BARE EQUIPMENT $360 $290 Implemented
KU0258 # 03 Y:1988 03 1988 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $604 $950 Implemented
KU0258 # 04 Y:1988 04 1988 INSULATE BARE EQUIPMENT $599 $600 Implemented
KU0258 # 05 Y:1988 05 1988 SHUT OFF PILOTS IN STANDBY EQUIPMENT $198 $0 Implemented
KU0258 # 06 Y:1988 06 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $235 $0 Implemented
KU0258 # 07 Y:1988 07 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $444 $376 Implemented
UD0168 # 01 Y:1985 01 1985 INSTALL SET-BACK TIMERS $2,610 $1,000 Implemented
UD0168 # 05 Y:1985 05 1985 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $506 $0 Implemented