Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

382

matching recommendations
Reset
SIC 3451 Screw Machine Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0261 # 10 Y:2004 10 2004 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $20,632 $400 Implemented
BD0261 # 11 Y:2004 11 2004 USE EVAPORATION TO CONCENTRATE MATERIAL $1,331 $2 Implemented
BD0261 # 12 Y:2004 12 2004 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $1,000 $240 Implemented
BD0261 # 13 Y:2004 13 2004 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $847 $102 Implemented
BD0261 # 14 Y:2004 14 2004 MINIMIZE WATER USAGE $702 $1,035 Not Implemented
BD0261 # 15 Y:2004 15 2004 INSTALL AUTOMATIC BOILER FUEL FEED SYSTEM $49,566 $91,500 Implemented
BD0261 # 16 Y:2004 16 2004 PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST $54,392 $210,000 Implemented
SU0178 # 01 Y:2004 01 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $26,400 $0 Implemented
SU0178 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,746 $527 Implemented
SU0178 # 03 Y:2004 03 2004 INSTALL OCCUPANCY SENSORS $580 $214 Implemented
SU0178 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,209 $20,138 Not Implemented
SU0178 # 05 Y:2004 05 2004 OPTIMIZE PLANT POWER FACTOR $5,392 $15,432 Implemented
TA0049 # 01 Y:2003 01 2003 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $573,800 $108,000 Not Implemented
TA0049 # 02 Y:2003 02 2003 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $27,239 $0 Implemented
TA0049 # 03 Y:2003 03 2003 CONTRACT A WOOD PALLET RECYCLING COMPANY $3,900 $0 Implemented
TA0049 # 04 Y:2003 04 2003 DISCONNECT BALLASTS $1,775 $3,096 Implemented
TA0049 # 05 Y:2003 05 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,088 $162 Implemented
OR0409 # 01 Y:2002 01 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,115 $33,646 Not Implemented
OR0409 # 02 Y:2002 02 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,918 $3,031 Not Implemented
OR0409 # 03 Y:2002 03 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,676 $560 Implemented
OR0409 # 04 Y:2002 04 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,472 $3,500 Implemented
OR0409 # 05 Y:2002 05 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,749 $0 Implemented
MA0492 # 01 Y:2001 01 2001 USE EVAPORATION TO CONCENTRATE MATERIAL $23,000 $10,000 Not Implemented
MA0492 # 02 Y:2001 02 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,800 $360 Implemented
MA0492 # 03 Y:2001 03 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,800 $15,000 Not Implemented