Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

194

matching recommendations
Reset
SIC 3452 Bolts, Nuts, Rivets, And Washers
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0139 # 11 Y:1999 11 1999 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $55,272 $5,000 Not Implemented
BD0139 # 12 Y:1999 12 1999 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $528 $250 Not Implemented
WI0317 # 01 Y:1998 01 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,682 $1,342 Not Implemented
WI0317 # 02 Y:1998 02 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $986 $0 Not Implemented
WI0317 # 03 Y:1998 03 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $597 $2,250 Not Implemented
WI0317 # 04 Y:1998 04 1998 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $1,611 $0 Implemented
WI0317 # 05 Y:1998 05 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,138 $740 Not Implemented
WI0317 # 06 Y:1998 06 1998 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $794 $0 Implemented
WI0317 # 07 Y:1998 07 1998 REPLACE CLOTH RAGS WITH PAPER TOWELS $400 $0 Not Implemented
WI0212 # 01 Y:1994 01 1994 INSULATE BARE EQUIPMENT $5,416 $492 Implemented
WI0212 # 02 Y:1994 02 1994 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $4,049 $500 Not Implemented
WI0212 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,829 $2,021 Not Implemented
WI0212 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $488 $1,760 Not Implemented
WI0212 # 05 Y:1994 05 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $978 $1,329 Not Implemented
WI0212 # 06 Y:1994 06 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $585 $370 Implemented
WI0212 # 07 Y:1994 07 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $543 $464 Not Implemented
WI0212 # 08 Y:1994 08 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $346 $960 Not Implemented
WI0212 # 09 Y:1994 09 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $147 $0 Not Implemented
WI0212 # 10 Y:1994 10 1994 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $3,000 $7,000 Implemented
WI0130 # 01 Y:1991 01 1991 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $33,213 $20,000 Not Implemented
WI0130 # 02 Y:1991 02 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $5,028 $0 Not Implemented
WI0130 # 03 Y:1991 03 1991 IMPROVE LUBRICATION PRACTICES $4,776 $0 Not Implemented
WI0130 # 04 Y:1991 04 1991 RECOVER WASTE HEAT FROM EQUIPMENT $1,068 $3,100 Not Implemented
WI0130 # 05 Y:1991 05 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,149 $1,920 Not Implemented
WI0130 # 06 Y:1991 06 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $565 $700 Not Implemented