Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

173

matching recommendations
Reset
SIC 346 Metal Forgings And Stampings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IP0201 # 04 Y:2024 04 2024 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $133,638 $39,257 n/a
IP0201 # 06 Y:2024 06 2024 INSTALL OCCUPANCY SENSORS $2,678 $1,198 n/a
IP0201 # 08 Y:2024 08 2024 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $10,830 $25,000 n/a
IP0201 # 07 Y:2024 07 2024 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,237 $2,101 n/a
IP0201 # 01 Y:2024 01 2024 TURN OFF EQUIPMENT WHEN NOT IN USE $55,084 $0 n/a
IP0201 # 03 Y:2024 03 2024 INSTALL SUB-METERING EQUIPMENT $3,904 $700 n/a
IP0201 # 05 Y:2024 05 2024 RECOVER WASTE HEAT FROM EQUIPMENT $4,991 $1,471 n/a
IP0201 # 02 Y:2024 02 2024 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $9,654 $0 n/a
UL2204 # 01 Y:2022 01 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,621 $22,425 Not Implemented
UL2204 # 06 Y:2022 06 2022 USE SOLAR HEAT TO MAKE ELECTRICTY $153,358 $1,265,937 Not Implemented
UL2204 # 07 Y:2022 07 2022 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $299 $1,156 Not Implemented
UL2204 # 04 Y:2022 04 2022 OPTIMIZE PLANT POWER FACTOR $38,344 $59,098 Not Implemented
UL2204 # 08 Y:2022 08 2022 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $84,924 $750,000 Not Implemented
UL2204 # 05 Y:2022 05 2022 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,168 $2,880 Not Implemented
UL2204 # 03 Y:2022 03 2022 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $16,260 $117,000 Not Implemented
UL2204 # 02 Y:2022 02 2022 INSTALL OCCUPANCY SENSORS $6,795 $4,853 Not Implemented
UD1035 # 02 Y:2022 02 2022 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $128 $0 Implemented
UD1035 # 05 Y:2022 05 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,106 $5,256 Implemented
UD1035 # 01 Y:2022 01 2022 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $22,050 $0 Implemented
UD1035 # 07 Y:2022 07 2022 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $10,297 $12,000 Not Implemented
UD1035 # 03 Y:2022 03 2022 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $29,591 $604 Not Implemented
UD1035 # 06 Y:2022 06 2022 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $150 $50 Not Implemented
UD1035 # 04 Y:2022 04 2022 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,603 $6,300 Not Implemented
IP0137 # 01 Y:2020 01 2020 TURN OFF EQUIPMENT WHEN NOT IN USE $2,249 $0 Implemented
IP0137 # 07 Y:2020 07 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,777 $4,138 Implemented