Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
125
matching recommendationsSIC | 346 | Metal Forgings And Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0250 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $180 | $540 | Not Implemented |
ND0250 # 06 Y:1996 | 06 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,218 | $967 | Implemented |
ND0250 # 08 Y:1996 | 08 | 1996 | REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE | $1,275 | $14,800 | Not Implemented |
ND0250 # 02 Y:1996 | 02 | 1996 | INSTALL OCCUPANCY SENSORS | $490 | $1,200 | Not Implemented |
ND0250 # 05 Y:1996 | 05 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $90 | $756 | Implemented |
ND0251 # 04 Y:1996 | 04 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $42 | $7 | n/a |
ND0251 # 09 Y:1996 | 09 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,292 | $360 | n/a |
ND0251 # 02 Y:1996 | 02 | 1996 | INSTALL OCCUPANCY SENSORS | $149 | $200 | n/a |
ND0251 # 10 Y:1996 | 10 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,510 | $360 | n/a |
ND0251 # 11 Y:1996 | 11 | 1996 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $18,549 | $660 | n/a |
ND0251 # 07 Y:1996 | 07 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,969 | $4,450 | n/a |
ND0251 # 08 Y:1996 | 08 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $39 | $60 | n/a |
ND0251 # 03 Y:1996 | 03 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $57 | $84 | n/a |
ND0251 # 05 Y:1996 | 05 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $409 | $850 | n/a |
ND0251 # 06 Y:1996 | 06 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,312 | $300 | n/a |
ND0251 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $263 | $397 | n/a |
SD0155 # 07 Y:1996 | 07 | 1996 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,318 | $1,100 | Implemented |
SD0155 # 06 Y:1996 | 06 | 1996 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $867 | $1,344 | Not Implemented |
SD0155 # 09 Y:1996 | 09 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,351 | $2,902 | Implemented |
SD0155 # 05 Y:1996 | 05 | 1996 | INSULATE BARE EQUIPMENT | $1,165 | $158 | Implemented |
SD0155 # 04 Y:1996 | 04 | 1996 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $1,401 | $1,127 | Not Implemented |
SD0155 # 08 Y:1996 | 08 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,662 | $500 | Implemented |
SD0155 # 12 Y:1996 | 12 | 1996 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $1,281 | $0 | Implemented |
SD0155 # 11 Y:1996 | 11 | 1996 | INSTALL OCCUPANCY SENSORS | $1,816 | $779 | Implemented |
SD0155 # 10 Y:1996 | 10 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,577 | $3,055 | Not Implemented |