Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,616
matching recommendationsSIC | 346 | Metal Forgings And Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0512 # 01 Y:2015 | 01 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $34,138 | $61,820 | Not Implemented |
SD0512 # 02 Y:2015 | 02 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $39,697 | $25,608 | Implemented |
SD0512 # 03 Y:2015 | 03 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,185 | $45,900 | Implemented |
SD0512 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,532 | $800 | Implemented |
SD0512 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $3,224 | $2,850 | Implemented |
SD0512 # 06 Y:2015 | 06 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,985 | $5,247 | Implemented |
SD0511 # 01 Y:2015 | 01 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,106 | $21,000 | Not Implemented |
SD0511 # 02 Y:2015 | 02 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,418 | $1,750 | Not Implemented |
SD0511 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,658 | $2,000 | Not Implemented |
SD0511 # 04 Y:2015 | 04 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,296 | $6,475 | Not Implemented |
SD0511 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $2,105 | $1,508 | Not Implemented |
SD0511 # 06 Y:2015 | 06 | 2015 | INSULATE BARE EQUIPMENT | $812 | $2,323 | Not Implemented |
WM0069 # 01 Y:2015 | 01 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $177,870 | $500,000 | Not Implemented |
WM0069 # 02 Y:2015 | 02 | 2015 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $30,131 | $24,450 | Implemented |
WM0069 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $31,322 | $95,000 | Not Implemented |
WM0069 # 04 Y:2015 | 04 | 2015 | REPLACE BOILER | $34,455 | $6,500 | Not Implemented |
WM0069 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,294 | $2,400 | Implemented |
WM0069 # 06 Y:2015 | 06 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $27,723 | $0 | Implemented |
WM0069 # 07 Y:2015 | 07 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,035 | $855 | Not Implemented |
WM0069 # 08 Y:2015 | 08 | 2015 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $6,282 | $14,000 | Not Implemented |
WM0069 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,822 | $6,100 | Implemented |
WM0069 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $1,379 | $1,500 | Not Implemented |
WM0069 # 11 Y:2015 | 11 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,423 | $1,600 | Not Implemented |
WM0068 # 01 Y:2015 | 01 | 2015 | USE PHOTOCELL CONTROLS | $363 | $420 | Not Implemented |
WM0068 # 02 Y:2015 | 02 | 2015 | INSTALL OCCUPANCY SENSORS | $514 | $515 | Not Implemented |