Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,616
matching recommendationsSIC | 346 | Metal Forgings And Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0538 # 06 Y:1995 | 06 | 1995 | OPTIMIZE PLANT POWER FACTOR | $4,892 | $5,000 | Implemented |
UD0444 # 01 Y:1994 | 01 | 1994 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $15,232 | $15,000 | Not Implemented |
UD0444 # 02 Y:1994 | 02 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,000 | $0 | Implemented |
UD0444 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $6,048 | $8,000 | Implemented |
UD0444 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,528 | $4,550 | Not Implemented |
UD0444 # 05 Y:1994 | 05 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,137 | $8,000 | Not Implemented |
IA0099 # 01 Y:1994 | 01 | 1994 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $22,684 | $0 | Implemented |
IA0099 # 02 Y:1994 | 02 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,414 | $1,400 | Implemented |
IA0099 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,352 | $500 | Implemented |
IA0099 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,278 | $2,340 | Implemented |
IA0099 # 05 Y:1994 | 05 | 1994 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,683 | $0 | Not Implemented |
IA0099 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,924 | $1,028 | Not Implemented |
IA0099 # 07 Y:1994 | 07 | 1994 | INSTALL OCCUPANCY SENSORS | $947 | $693 | Not Implemented |
IA0099 # 08 Y:1994 | 08 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $1,201 | $1,300 | Not Implemented |
IA0099 # 09 Y:1994 | 09 | 1994 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $535 | $0 | Not Implemented |
IA0094 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,255 | $315 | Implemented |
IA0094 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,502 | $1,430 | Implemented |
IA0094 # 03 Y:1994 | 03 | 1994 | INSTALL OCCUPANCY SENSORS | $2,191 | $1,224 | Not Implemented |
IA0094 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,523 | $10,378 | Implemented |
IA0094 # 05 Y:1994 | 05 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,916 | $390 | Not Implemented |
IA0094 # 06 Y:1994 | 06 | 1994 | INSULATE BARE EQUIPMENT | $184 | $68 | Not Implemented |
BD0012 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,731 | $74,007 | Implemented |
BD0012 # 02 Y:1994 | 02 | 1994 | INSTALL OCCUPANCY SENSORS | $501 | $500 | Implemented |
BD0012 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,853 | $6,580 | Implemented |
BD0012 # 04 Y:1994 | 04 | 1994 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $35,651 | $1,500 | Not Implemented |