Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
24
matching recommendationsSIC | 346 | Metal Forgings And Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0658 # 07 Y:2002 | 07 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $749 | $0 | Not Implemented |
UD0658 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,826 | $8,905 | Not Implemented |
UD0658 # 05 Y:2002 | 05 | 2002 | USE RADIANT HEATER FOR SPOT HEATING | $4,586 | $7,938 | Not Implemented |
UD0658 # 04 Y:2002 | 04 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,863 | $1,050 | Not Implemented |
UD0658 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,063 | $8,000 | Implemented |
UD0658 # 02 Y:2002 | 02 | 2002 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $20,837 | $16,100 | Implemented |
UD0658 # 01 Y:2002 | 01 | 2002 | $962,280 | $448,000 | Implemented | |
UD0649 # 07 Y:2002 | 07 | 2002 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $1,615 | $1,275 | Not Implemented |
UD0649 # 11 Y:2002 | 11 | 2002 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $92 | $0 | Implemented |
UD0649 # 10 Y:2002 | 10 | 2002 | MINIMIZE WATER USAGE | $373 | $0 | Implemented |
UD0649 # 09 Y:2002 | 09 | 2002 | INSULATE BARE EQUIPMENT | $502 | $1,640 | Not Implemented |
UD0649 # 08 Y:2002 | 08 | 2002 | INSTALL OCCUPANCY SENSORS | $512 | $113 | Not Implemented |
UD0649 # 06 Y:2002 | 06 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,082 | $1,008 | Not Implemented |
UD0649 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,306 | $6,000 | Implemented |
UD0649 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,660 | $6,691 | Implemented |
UD0649 # 03 Y:2002 | 03 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,835 | $3,500 | Not Implemented |
UD0649 # 02 Y:2002 | 02 | 2002 | $16,650 | $15,000 | Not Implemented | |
UD0649 # 01 Y:2002 | 01 | 2002 | $72,080 | $3,600 | Not Implemented | |
UD0640 # 01 Y:2002 | 01 | 2002 | $181,200 | $252,000 | Not Implemented | |
UD0640 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,815 | $7,700 | Implemented |
UD0640 # 05 Y:2002 | 05 | 2002 | OPTIMIZE PLANT POWER FACTOR | $2,305 | $6,500 | Not Implemented |
UD0640 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,719 | $11,324 | Not Implemented |
UD0640 # 03 Y:2002 | 03 | 2002 | ADJUST VENTS TO MINIMIZE ENERGY USE | $37,432 | $39,000 | Not Implemented |
UD0640 # 02 Y:2002 | 02 | 2002 | BURN A LESS EXPENSIVE GRADE OF FUEL | $57,385 | $82,200 | Implemented |