Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsSIC | 3462 | Iron And Steel Forgings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0333 # 08 Y:2025 | 08 | 2025 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $596 | $1,186 | n/a |
TT0333 # 07 Y:2025 | 07 | 2025 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,569 | $3,000 | n/a |
TT0333 # 06 Y:2025 | 06 | 2025 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $3,915 | $1,640 | n/a |
TT0333 # 05 Y:2025 | 05 | 2025 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,400 | $21,000 | n/a |
TT0333 # 04 Y:2025 | 04 | 2025 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,979 | $900 | n/a |
TT0333 # 03 Y:2025 | 03 | 2025 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,881 | $94 | n/a |
TT0333 # 02 Y:2025 | 02 | 2025 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $39,658 | $1,500 | n/a |
TT0333 # 01 Y:2025 | 01 | 2025 | USE SOLAR HEAT TO MAKE ELECTRICTY | $88,627 | $794,938 | n/a |
AR0182 # 02 Y:2000 | 02 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $351 | $0 | Implemented |
AR0182 # 01 Y:2000 | 01 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $916 | $1,360 | Not Implemented |
AR0182 # 03 Y:2000 | 03 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $496 | $180 | Not Implemented |
AR0182 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,868 | $130 | Implemented |
AR0182 # 05 Y:2000 | 05 | 2000 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $60,765 | $150,000 | Implemented |
AR0182 # 06 Y:2000 | 06 | 2000 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $4,468 | $175 | Implemented |
AR0182 # 07 Y:2000 | 07 | 2000 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $222,939 | $244,000 | Not Implemented |
TN0641 # 05 Y:1998 | 05 | 1998 | USE OPTIMUM THICKNESS INSULATION | $240 | $550 | Not Implemented |
TN0641 # 06 Y:1998 | 06 | 1998 | USE A RAG RECYCLE SERVICE | $140 | $0 | Not Implemented |
TN0641 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,130 | $980 | Implemented |
TN0641 # 03 Y:1998 | 03 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $3,560 | $2,500 | Implemented |
TN0641 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,810 | $5,000 | Implemented |
TN0641 # 01 Y:1998 | 01 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $462,700 | $440,300 | Not Implemented |
TN0491 # 03 Y:1993 | 03 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $991 | $320 | Implemented |
TN0491 # 02 Y:1993 | 02 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $1,810 | $2,260 | Implemented |
TN0491 # 01 Y:1993 | 01 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,084 | $3,680 | Not Implemented |
TN0491 # 07 Y:1993 | 07 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $158 | $520 | Not Implemented |