Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

86

matching recommendations
Reset
SIC 3462 Iron And Steel Forgings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TR0061 # 04 Y:2024 04 2024 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $16,588 $55,200 n/a
TR0061 # 03 Y:2024 03 2024 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $2,219 $4,350 n/a
TR0061 # 02 Y:2024 02 2024 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $9,288 $17,929 n/a
TR0061 # 01 Y:2024 01 2024 USE SOLAR HEAT TO MAKE ELECTRICTY $121,083 $551,388 n/a
TR0061 # 05 Y:2024 05 2024 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,297 $728 n/a
AM0825 # 03 Y:2021 03 2021 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $8,070 $4,250 Implemented
AM0825 # 01 Y:2021 01 2021 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,860 $5,000 Implemented
AM0825 # 05 Y:2021 05 2021 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,310 $45 Not Implemented
AM0825 # 02 Y:2021 02 2021 TURN OFF EQUIPMENT WHEN NOT IN USE $8,900 $0 Not Implemented
AM0825 # 04 Y:2021 04 2021 USE SYNTHETIC LUBRICANT $2,400 $300 Not Implemented
TR0020 # 06 Y:2020 06 2020 USE SOLAR HEAT TO MAKE ELECTRICTY $25,280 $40,101 Not Implemented
TR0020 # 01 Y:2020 01 2020 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,021 $0 Implemented
TR0020 # 03 Y:2020 03 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $558 $150 Implemented
TR0020 # 05 Y:2020 05 2020 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $12,445 $810 Implemented
TR0020 # 02 Y:2020 02 2020 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,748 $0 Implemented
TR0020 # 04 Y:2020 04 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,914 $3,155 Implemented
TA0114 # 02 Y:2006 02 2006 USE RADIANT HEATER FOR SPOT HEATING $21,785 $14,190 Implemented
TA0114 # 01 Y:2006 01 2006 UPGRADE CONTROLS ON COMPRESSORS $66,794 $14,400 Implemented
TA0114 # 04 Y:2006 04 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,234 $60 Implemented
TA0114 # 05 Y:2006 05 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $684 $0 Not Implemented
TA0114 # 06 Y:2006 06 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $117 $270 Implemented
TA0114 # 03 Y:2006 03 2006 INSULATE BARE EQUIPMENT $24,225 $1,020 Implemented
TA0093 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,110 $0 Not Implemented
TA0093 # 02 Y:2005 02 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $12,125 $10 Not Implemented
TA0093 # 03 Y:2005 03 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $2,560 $0 Not Implemented