Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
164
matching recommendationsSIC | 3463 | Nonferrous Forgings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA3011 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,307 | $26,402 | Not Implemented |
UA3011 # 10 Y:2011 | 10 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $13,650 | $9,480 | Not Implemented |
UA3011 # 05 Y:2011 | 05 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,304 | $1,800 | Not Implemented |
UA3011 # 09 Y:2011 | 09 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,493 | $70,000 | Not Implemented |
UA3011 # 12 Y:2011 | 12 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $843 | $50 | Implemented |
UA3011 # 02 Y:2011 | 02 | 2011 | USE PHOTOCELL CONTROLS | $575 | $225 | Implemented |
UA3011 # 13 Y:2011 | 13 | 2011 | INSULATE BARE EQUIPMENT | $5,251 | $1,503 | Not Implemented |
UM0328 # 07 Y:2007 | 07 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,637 | $50,000 | Not Implemented |
UM0328 # 13 Y:2007 | 13 | 2007 | INSULATE BARE EQUIPMENT | $493 | $307 | Not Implemented |
UM0328 # 06 Y:2007 | 06 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,450 | $1,000 | Not Implemented |
UM0328 # 09 Y:2007 | 09 | 2007 | INSULATE BARE EQUIPMENT | $2,032 | $1,604 | Not Implemented |
UM0328 # 12 Y:2007 | 12 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $515 | $1,000 | Not Implemented |
UM0328 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,957 | $4,000 | Not Implemented |
UM0328 # 10 Y:2007 | 10 | 2007 | INSULATE BARE EQUIPMENT | $1,625 | $1,238 | Implemented |
UM0328 # 11 Y:2007 | 11 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,083 | $1,350 | Not Implemented |
UM0328 # 03 Y:2007 | 03 | 2007 | OPTIMIZE PLANT POWER FACTOR | $6,128 | $8,790 | Not Implemented |
UM0328 # 08 Y:2007 | 08 | 2007 | INSTALL OCCUPANCY SENSORS | $2,167 | $644 | Not Implemented |
UM0328 # 01 Y:2007 | 01 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,110 | $1,000 | Implemented |
UM0328 # 04 Y:2007 | 04 | 2007 | COVER OPEN TANKS | $5,154 | $1,500 | Not Implemented |
UM0328 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,079 | $45,000 | Not Implemented |
SD0383 # 04 Y:2006 | 04 | 2006 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $5,803 | $900 | n/a |
SD0383 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,420 | $260 | n/a |
SD0383 # 05 Y:2006 | 05 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,966 | $4,300 | n/a |
SD0383 # 03 Y:2006 | 03 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,249 | $26,550 | n/a |
SD0383 # 01 Y:2006 | 01 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $33,958 | $0 | n/a |