Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
642
matching recommendationsSIC | 3465 | Automotive Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0382 # 04 Y:1992 | 04 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $888 | $645 | Not Implemented |
KU0382 # 05 Y:1992 | 05 | 1992 | INSTALL SET-BACK TIMERS | $332 | $700 | Not Implemented |
GT0406 # 01 Y:1990 | 01 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $772 | $2,430 | Not Implemented |
GT0406 # 02 Y:1990 | 02 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,787 | $14,000 | Not Implemented |
GT0406 # 03 Y:1990 | 03 | 1990 | USE OPTIMUM THICKNESS INSULATION | $5,930 | $98 | Not Implemented |
GT0406 # 04 Y:1990 | 04 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,920 | $815 | Not Implemented |
GT0406 # 05 Y:1990 | 05 | 1990 | IMPROVE LUBRICATION PRACTICES | $3,390 | $0 | Not Implemented |
GT0406 # 06 Y:1990 | 06 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,125 | $1,633 | Not Implemented |
GT0406 # 07 Y:1990 | 07 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,678 | $21,372 | Not Implemented |
UD0263 # 01 Y:1988 | 01 | 1988 | OPTIMIZE PLANT POWER FACTOR | $4,019 | $15,000 | Implemented |
UD0263 # 02 Y:1988 | 02 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,000 | $0 | Not Implemented |
UD0263 # 03 Y:1988 | 03 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,423 | $1,000 | Implemented |
UD0263 # 04 Y:1988 | 04 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,534 | $0 | Not Implemented |
UD0263 # 05 Y:1988 | 05 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,981 | $1,500 | Implemented |
UD0263 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,295 | $9,000 | Implemented |
UD0247 # 01 Y:1988 | 01 | 1988 | COMBINE UTILITY METERS | $1,416 | $3,000 | Not Implemented |
UD0247 # 02 Y:1988 | 02 | 1988 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,816 | $0 | Implemented |
UD0247 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $818 | $2,000 | Not Implemented |
UD0247 # 04 Y:1988 | 04 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,332 | $1,500 | Implemented |
UD0247 # 05 Y:1988 | 05 | 1988 | OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS | $1,405 | $76 | Implemented |
TN0324 # 01 Y:1987 | 01 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,756 | $300 | Implemented |
TN0324 # 02 Y:1987 | 02 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $906 | $585 | Implemented |
TN0324 # 03 Y:1987 | 03 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,612 | $4,800 | Implemented |
TN0324 # 04 Y:1987 | 04 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,386 | $2,836 | Not Implemented |
TN0324 # 05 Y:1987 | 05 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,322 | $1,120 | Implemented |