Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
642
matching recommendationsSIC | 3465 | Automotive Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0324 # 06 Y:1987 | 06 | 1987 | ADJUST VENTS TO MINIMIZE ENERGY USE | $967 | $0 | Implemented |
TN0324 # 07 Y:1987 | 07 | 1987 | IMPROVE LUBRICATION PRACTICES | $951 | $1,500 | Not Implemented |
TN0324 # 08 Y:1987 | 08 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $822 | $1,360 | Implemented |
TN0324 # 09 Y:1987 | 09 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $790 | $192 | Implemented |
TN0324 # 10 Y:1987 | 10 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $139 | $45 | Not Implemented |
UD0131 # 01 Y:1984 | 01 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,171 | $0 | Implemented |
UD0131 # 02 Y:1984 | 02 | 1984 | REDUCE GLAZED AREAS IN BUILDINGS | $17,464 | $50,000 | Implemented |
UD0131 # 03 Y:1984 | 03 | 1984 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,070 | $8,000 | Implemented |
UD0131 # 04 Y:1984 | 04 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,853 | $800 | Implemented |
UD0131 # 05 Y:1984 | 05 | 1984 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $2,576 | $4,000 | Implemented |
UD0131 # 06 Y:1984 | 06 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,453 | $20,000 | Implemented |
GT0166 # 01 Y:1983 | 01 | 1983 | COVER OPEN TANKS | $15,260 | $6,300 | Not Implemented |
GT0166 # 02 Y:1983 | 02 | 1983 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,800 | $21,480 | Not Implemented |
GT0166 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,300 | $4,538 | Not Implemented |
GT0166 # 04 Y:1983 | 04 | 1983 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,570 | $200 | Not Implemented |
GT0166 # 05 Y:1983 | 05 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,811 | $500 | Not Implemented |
GT0166 # 06 Y:1983 | 06 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,370 | $127 | Not Implemented |