Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
60
matching recommendationsSIC | 3465 | Automotive Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0243 # 02 Y:2021 | 02 | 2021 | USE PHOTOCELL CONTROLS | $8,709 | $24,348 | Not Implemented |
UA0243 # 03 Y:2021 | 03 | 2021 | OPTIMIZE PLANT POWER FACTOR | $45,219 | $10,941 | Implemented |
UA0243 # 04 Y:2021 | 04 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,058 | $9,682 | Implemented |
UA0243 # 05 Y:2021 | 05 | 2021 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,529 | $100 | Not Implemented |
UA0243 # 06 Y:2021 | 06 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,133 | $4,930 | Not Implemented |
UA0243 # 01 Y:2021 | 01 | 2021 | INSTALL OCCUPANCY SENSORS | $6,816 | $22,649 | Not Implemented |
UA0240 # 01 Y:2021 | 01 | 2021 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,059 | $800 | Implemented |
UA0240 # 02 Y:2021 | 02 | 2021 | OPTIMIZE PLANT POWER FACTOR | $8,528 | $60,000 | Implemented |
UA0240 # 03 Y:2021 | 03 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,894 | $9,682 | Implemented |
UA0222 # 01 Y:2020 | 01 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,232 | $92,405 | Implemented |
UA0222 # 06 Y:2020 | 06 | 2020 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $22,556 | $500 | Not Implemented |
UA0222 # 05 Y:2020 | 05 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,178 | $50 | Not Implemented |
UA0222 # 04 Y:2020 | 04 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,527 | $7,775 | Implemented |
UA0222 # 03 Y:2020 | 03 | 2020 | COMBINE UTILITY METERS | $26,371 | $60,000 | Not Implemented |
UA0222 # 02 Y:2020 | 02 | 2020 | OPTIMIZE PLANT POWER FACTOR | $12,593 | $6,955 | Not Implemented |
UA0173 # 06 Y:2017 | 06 | 2017 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $35,206 | $1,000 | Not Implemented |
UA0173 # 03 Y:2017 | 03 | 2017 | INSTALL OCCUPANCY SENSORS | $2,924 | $880 | Implemented |
UA0173 # 02 Y:2017 | 02 | 2017 | USE PHOTOCELL CONTROLS | $5,531 | $2,748 | Implemented |
UA0173 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $62,936 | $136,836 | Not Implemented |
UA0173 # 04 Y:2017 | 04 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $13,905 | $500 | Not Implemented |
UA0173 # 05 Y:2017 | 05 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,474 | $5,695 | Implemented |
UA0173 # 07 Y:2017 | 07 | 2017 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $21,010 | $28,800 | Not Implemented |
UA0173 # 08 Y:2017 | 08 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,811 | $150 | Implemented |
UA3023 # 10 Y:2012 | 10 | 2012 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,216 | $430 | Not Implemented |
UA3023 # 09 Y:2012 | 09 | 2012 | DISCONNECT BALLASTS | $3,927 | $810 | Implemented |