Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
62
matching recommendationsSIC | 3465 | Automotive Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA3023 # 09 Y:2012 | 09 | 2012 | DISCONNECT BALLASTS | $3,927 | $810 | Implemented |
UA3023 # 08 Y:2012 | 08 | 2012 | DISCONNECT BALLASTS | $4,820 | $810 | Implemented |
UA3023 # 07 Y:2012 | 07 | 2012 | DISCONNECT BALLASTS | $6,783 | $1,013 | Implemented |
UA3023 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $26,924 | $9,695 | Not Implemented |
UA3023 # 05 Y:2012 | 05 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $28,652 | $2,400 | Not Implemented |
UA3023 # 04 Y:2012 | 04 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,914 | $180 | Implemented |
UA3023 # 03 Y:2012 | 03 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $9,242 | $680 | Not Implemented |
UA3023 # 02 Y:2012 | 02 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $27,110 | $2,162 | Not Implemented |
UA3023 # 01 Y:2012 | 01 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $90,505 | $55,107 | Not Implemented |
UA3023 # 10 Y:2012 | 10 | 2012 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,216 | $430 | Not Implemented |
UK1212 # 02 Y:2012 | 02 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $14,492 | $15,000 | Not Implemented |
UK1212 # 08 Y:2012 | 08 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $609 | $990 | Not Implemented |
UK1212 # 06 Y:2012 | 06 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,607 | $400 | Not Implemented |
UK1212 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,205 | $4,270 | Not Implemented |
UK1212 # 09 Y:2012 | 09 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $17,314 | $0 | Not Implemented |
UK1212 # 10 Y:2012 | 10 | 2012 | OPTIMIZE PLANT POWER FACTOR | $4,850 | $7,500 | Not Implemented |
UK1212 # 11 Y:2012 | 11 | 2012 | PAY UTILITY BILLS ON TIME | $1,535 | $0 | Implemented |
UK1212 # 05 Y:2012 | 05 | 2012 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $4,209 | $3,430 | Implemented |
UK1212 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,414 | $26,320 | Implemented |
UK1212 # 04 Y:2012 | 04 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,314 | $2,240 | Implemented |
UK1212 # 01 Y:2012 | 01 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $15,105 | $14,500 | Not Implemented |
UM0408 # 06 Y:2012 | 06 | 2012 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $1,364 | $0 | Implemented |
UM0408 # 05 Y:2012 | 05 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $595 | $100 | Implemented |
UM0408 # 04 Y:2012 | 04 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,447 | $200 | Not Implemented |
UM0408 # 01 Y:2012 | 01 | 2012 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $13,566 | $16,700 | Not Implemented |