Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
967
matching recommendationsSIC | 3469 | Metal Stampings, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0750 # 01 Y:2015 | 01 | 2015 | REDUCE VENTILATION AIR | $18,184 | $10,420 | Not Implemented |
MA0750 # 02 Y:2015 | 02 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $16,398 | $7,000 | Not Implemented |
MA0750 # 03 Y:2015 | 03 | 2015 | REDUCE VENTILATION AIR | $15,229 | $15,000 | Not Implemented |
MA0750 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,208 | $3,000 | Not Implemented |
WM0068 # 01 Y:2015 | 01 | 2015 | USE PHOTOCELL CONTROLS | $363 | $420 | Not Implemented |
WM0068 # 02 Y:2015 | 02 | 2015 | INSTALL OCCUPANCY SENSORS | $514 | $515 | Not Implemented |
WM0068 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $38,673 | $140,000 | Not Implemented |
WM0068 # 04 Y:2015 | 04 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,964 | $30,000 | Not Implemented |
WM0068 # 05 Y:2015 | 05 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,423 | $3,575 | Not Implemented |
WM0068 # 06 Y:2015 | 06 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,948 | $5,400 | Not Implemented |
WM0068 # 07 Y:2015 | 07 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,873 | $2,860 | Implemented |
WM0068 # 08 Y:2015 | 08 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,592 | $990 | Implemented |
WM0068 # 09 Y:2015 | 09 | 2015 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $6,440 | $3,575 | Implemented |
WM0068 # 10 Y:2015 | 10 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,810 | $2,627 | Not Implemented |
WM0060 # 01 Y:2015 | 01 | 2015 | REPLACE BOILER | $24,302 | $20,000 | Not Implemented |
WM0060 # 02 Y:2015 | 02 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $7,761 | $2,291 | Implemented |
WM0060 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,355 | $0 | Implemented |
WM0060 # 04 Y:2015 | 04 | 2015 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $3,701 | $1,218 | Implemented |
WM0060 # 05 Y:2015 | 05 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $1,080 | $110 | Implemented |
WM0060 # 06 Y:2015 | 06 | 2015 | INSTALL OCCUPANCY SENSORS | $786 | $3,000 | Implemented |
WM0060 # 07 Y:2015 | 07 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $680 | $255 | Implemented |
WV0489 # 06 Y:2014 | 06 | 2014 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,770 | $1,000 | Not Implemented |
WV0489 # 11 Y:2014 | 11 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $564 | $443 | Not Implemented |
WV0489 # 10 Y:2014 | 10 | 2014 | INSTALL SET-BACK TIMERS | $812 | $1,375 | Not Implemented |
WV0489 # 09 Y:2014 | 09 | 2014 | INSTALL OCCUPANCY SENSORS | $965 | $620 | Not Implemented |