Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0097 # 05 Y:1994 | 05 | 1994 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,331 | $2,205 | Implemented |
SD0097 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,480 | $3,045 | Implemented |
SD0097 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $613 | $300 | Implemented |
HO0091 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $289 | $1,093 | Implemented |
HO0091 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $203 | $483 | Implemented |
HO0091 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,017 | $1,493 | Implemented |
WI0215 # 04 Y:1994 | 04 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $848 | $1,400 | Implemented |
WI0215 # 05 Y:1994 | 05 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $229 | $500 | Implemented |
MA0312 # 04 Y:1994 | 04 | 1994 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $372 | $1,094 | Implemented |
MA0312 # 05 Y:1994 | 05 | 1994 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $3,394 | $35,728 | Implemented |
MA0312 # 02 Y:1994 | 02 | 1994 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $4,017 | $80,000 | Implemented |
OR0210 # 04 Y:1994 | 04 | 1994 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $124,000 | $118,900 | Implemented |
OR0210 # 02 Y:1994 | 02 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $220 | $300 | Implemented |
OR0210 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $43 | $139 | Implemented |
UM0009 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,936 | $6,420 | Implemented |
UM0009 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,061 | $18,721 | Implemented |
UM0009 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $262 | $800 | Implemented |
UM0009 # 06 Y:1994 | 06 | 1994 | COVER OPEN TANKS | $4,163 | $2,440 | Implemented |
UM0009 # 09 Y:1994 | 09 | 1994 | INSTALL / REPAIR INSULATION ON STEAM LINES | $930 | $196 | Implemented |
UM0009 # 10 Y:1994 | 10 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,829 | $1,500 | Implemented |
UM0009 # 11 Y:1994 | 11 | 1994 | USE RADIANT HEATER FOR SPOT HEATING | $8,161 | $21,400 | Implemented |
OR0209 # 03 Y:1994 | 03 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $274 | $0 | Implemented |
OR0209 # 05 Y:1994 | 05 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $185 | $248 | Implemented |
OR0209 # 02 Y:1994 | 02 | 1994 | IMPROVE COMBUSTION CONTROL CAPABILITY | $27,860 | $12,000 | Implemented |
OR0209 # 06 Y:1994 | 06 | 1994 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $67,700 | $260,000 | Implemented |