Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,577
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0484 # 03 Y:2019 | 03 | 2019 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $22,670 | $15,784 | Not Implemented |
SU0484 # 04 Y:2019 | 04 | 2019 | REPLACE BOILER | $168,017 | $185,420 | Not Implemented |
SU0484 # 05 Y:2019 | 05 | 2019 | INSTALL / REPAIR INSULATION ON STEAM LINES | $236 | $318 | Implemented |
SU0484 # 06 Y:2019 | 06 | 2019 | REDUCE VENTILATION AIR | $514 | $929 | Implemented |
SU0484 # 07 Y:2019 | 07 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,516 | $4,046 | Implemented |
SU0484 # 08 Y:2019 | 08 | 2019 | INSTALL OCCUPANCY SENSORS | $69 | $30 | Implemented |
IP0123 # 01 Y:2019 | 01 | 2019 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $286 | $7 | Implemented |
IP0123 # 02 Y:2019 | 02 | 2019 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $248 | $0 | Implemented |
IP0123 # 03 Y:2019 | 03 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $442 | $70 | Implemented |
IP0123 # 04 Y:2019 | 04 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $503 | $100 | Not Implemented |
IP0123 # 05 Y:2019 | 05 | 2019 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,980 | $440 | Implemented |
IP0123 # 06 Y:2019 | 06 | 2019 | OPTIMIZE PLANT POWER FACTOR | $5,541 | $9,685 | Not Implemented |
IP0123 # 07 Y:2019 | 07 | 2019 | INSULATE BARE EQUIPMENT | $96 | $200 | Not Implemented |
IP0123 # 08 Y:2019 | 08 | 2019 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $758 | $2,290 | Implemented |
IP0123 # 09 Y:2019 | 09 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,165 | $13,663 | Implemented |
IP0123 # 10 Y:2019 | 10 | 2019 | INSULATE BARE EQUIPMENT | $153 | $692 | Not Implemented |
GT0925 # 01 Y:2019 | 01 | 2019 | INSTALL AUTOMATIC STACK DAMPER | $16,903 | $6,764 | Not Implemented |
GT0925 # 02 Y:2019 | 02 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,524 | $1,100 | Implemented |
GT0925 # 03 Y:2019 | 03 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,005 | $3,500 | Not Implemented |
GT0925 # 04 Y:2019 | 04 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,266 | $9,527 | Implemented |
GT0925 # 05 Y:2019 | 05 | 2019 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,177 | $2,167 | Implemented |
GT0925 # 06 Y:2019 | 06 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,358 | $8,787 | Not Implemented |
IC0211 # 01 Y:2019 | 01 | 2019 | USE RADIANT HEATER FOR SPOT HEATING | $5,999 | $9,168 | Not Implemented |
IC0211 # 02 Y:2019 | 02 | 2019 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,310 | $18,709 | Implemented |
IC0211 # 03 Y:2019 | 03 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,768 | $42,206 | Implemented |