Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,577
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0459 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $440 | $560 | Not Implemented |
CO0459 # 07 Y:2000 | 07 | 2000 | INSULATE BARE EQUIPMENT | $350 | $80 | Not Implemented |
CO0459 # 08 Y:2000 | 08 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,070 | $9,130 | Not Implemented |
CO0459 # 09 Y:2000 | 09 | 2000 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $2,980 | $0 | Not Implemented |
CO0459 # 10 Y:2000 | 10 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $600 | $0 | Implemented |
DS0156 # 01 Y:2000 | 01 | 2000 | INSULATE BARE EQUIPMENT | $35,975 | $8,213 | Not Implemented |
DS0156 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $253 | $600 | Implemented |
DS0156 # 03 Y:2000 | 03 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,795 | $4,230 | Not Implemented |
DS0156 # 04 Y:2000 | 04 | 2000 | METER WASTE WATER | $9,582 | $1,200 | Implemented |
DS0156 # 05 Y:2000 | 05 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $9,336 | $-27,608 | Implemented |
DS0156 # 06 Y:2000 | 06 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $50,436 | $132,877 | Not Implemented |
DS0157 # 01 Y:2000 | 01 | 2000 | USE OPTIMUM THICKNESS INSULATION | $2,370 | $688 | Not Implemented |
DS0157 # 02 Y:2000 | 02 | 2000 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $5,432 | $800 | Not Implemented |
DS0157 # 03 Y:2000 | 03 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,297 | $0 | Not Implemented |
WI0364 # 01 Y:2000 | 01 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $20,162 | $0 | Implemented |
WI0364 # 02 Y:2000 | 02 | 2000 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $7,614 | $15,000 | Not Implemented |
WI0364 # 03 Y:2000 | 03 | 2000 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $6,918 | $20,750 | Not Implemented |
WI0364 # 04 Y:2000 | 04 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,730 | $740 | Not Implemented |
WI0364 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $489 | $90 | Not Implemented |
WI0364 # 06 Y:2000 | 06 | 2000 | INSULATE BARE EQUIPMENT | $1,567 | $3,871 | Not Implemented |
WI0364 # 07 Y:2000 | 07 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $594 | $438 | Not Implemented |
DS0154 # 01 Y:2000 | 01 | 2000 | INSULATE BARE EQUIPMENT | $1,239 | $864 | Implemented |
DS0154 # 02 Y:2000 | 02 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,609 | $10,510 | Not Implemented |
DS0154 # 03 Y:2000 | 03 | 2000 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $2,737 | $8,160 | Not Implemented |
DS0154 # 04 Y:2000 | 04 | 2000 | RECYCLE CLEANING SOLVENT AND REUSE | $18,740 | $17,676 | Implemented |