Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,577
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0429 # 05 Y:1998 | 05 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $730 | $280 | Not Implemented |
AM0334 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $18,200 | $22,300 | Implemented |
AM0334 # 02 Y:1998 | 02 | 1998 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $11,680 | $40,600 | Not Implemented |
AM0334 # 03 Y:1998 | 03 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,900 | $0 | Implemented |
AM0334 # 04 Y:1998 | 04 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,000 | $0 | Not Implemented |
AM0334 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,300 | $1,000 | Implemented |
AM0334 # 06 Y:1998 | 06 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,070 | $35 | Implemented |
AM0334 # 07 Y:1998 | 07 | 1998 | CONVERT TO AQUEOUS CLEANING SYSTEM | $1,260 | $1,030 | Implemented |
AM0334 # 08 Y:1998 | 08 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $165 | $340 | Not Implemented |
AM0334 # 09 Y:1998 | 09 | 1998 | USE A RAG RECYCLE SERVICE | $310 | $0 | Implemented |
AM0334 # 10 Y:1998 | 10 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $300 | $0 | Implemented |
AM0334 # 11 Y:1998 | 11 | 1998 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $220 | $0 | Implemented |
UD0557 # 01 Y:1998 | 01 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $42,942 | $12,000 | Implemented |
UD0557 # 02 Y:1998 | 02 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $60,203 | $0 | Implemented |
UD0557 # 03 Y:1998 | 03 | 1998 | RECYCLE CLEANING SOLVENT AND REUSE | $9,078 | $0 | Not Implemented |
UD0557 # 04 Y:1998 | 04 | 1998 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $7,643 | $1,440 | Not Implemented |
UD0557 # 05 Y:1998 | 05 | 1998 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,636 | $6,680 | Not Implemented |
UD0557 # 06 Y:1998 | 06 | 1998 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,778 | $0 | Not Implemented |
NC0150 # 01 Y:1998 | 01 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $920 | $400 | Not Implemented |
NC0150 # 02 Y:1998 | 02 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,383 | $819 | Not Implemented |
NC0150 # 03 Y:1998 | 03 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $729 | $1,532 | Not Implemented |
NC0150 # 04 Y:1998 | 04 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $244 | $800 | Implemented |
NC0150 # 05 Y:1998 | 05 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,244 | $4,400 | Implemented |
NC0150 # 06 Y:1998 | 06 | 1998 | USE ADSORPTION, ION EXCHANGE TO REMOVE CONTAMINANTS | $14,434 | $500 | Not Implemented |
NC0150 # 07 Y:1998 | 07 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $45,216 | $16,000 | Not Implemented |