Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,567
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0498 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $656 | $700 | Not Implemented |
UD0498 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,731 | $6,298 | Not Implemented |
OK0500 # 01 Y:1996 | 01 | 1996 | PURCHASE HIGH MATERIALS IN RETURNABLE BULK CONTAINERS | $6,013 | $0 | Implemented |
OK0500 # 02 Y:1996 | 02 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,222 | $11,250 | Not Implemented |
OK0500 # 03 Y:1996 | 03 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,125 | $620 | Implemented |
OK0500 # 04 Y:1996 | 04 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $420 | $1,300 | Implemented |
OK0500 # 05 Y:1996 | 05 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $396 | $35 | Not Implemented |
OK0500 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20 | $30 | Implemented |
SD0150 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,102 | $21,570 | Implemented |
SD0150 # 02 Y:1996 | 02 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,242 | $3,920 | Implemented |
SD0150 # 03 Y:1996 | 03 | 1996 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $10,042 | $4,160 | Implemented |
SD0150 # 04 Y:1996 | 04 | 1996 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,408 | $3,077 | Implemented |
SD0150 # 05 Y:1996 | 05 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,368 | $5,825 | Not Implemented |
SD0150 # 06 Y:1996 | 06 | 1996 | MINIMIZE WATER USAGE | $7,565 | $3,410 | Implemented |
SD0150 # 07 Y:1996 | 07 | 1996 | USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE | $34,791 | $5,000 | Implemented |
DS0051 # 03 Y:1996 | 03 | 1996 | INSULATE BARE EQUIPMENT | $1,434 | $1,257 | Implemented |
DS0051 # 04 Y:1996 | 04 | 1996 | TREAT AND REUSE RINSE WATERS | $8,506 | $17,190 | Implemented |
DS0051 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $305 | $1,149 | Not Implemented |
DS0051 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,084 | $3,765 | Not Implemented |
SD0146 # 01 Y:1996 | 01 | 1996 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $857 | $150 | Implemented |
SD0146 # 02 Y:1996 | 02 | 1996 | INSULATE BARE EQUIPMENT | $530 | $659 | Implemented |
SD0146 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $515 | $564 | Implemented |
SD0146 # 04 Y:1996 | 04 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $373 | $710 | Implemented |
SD0146 # 05 Y:1996 | 05 | 1996 | INSTALL OCCUPANCY SENSORS | $595 | $394 | Implemented |
SD0146 # 06 Y:1996 | 06 | 1996 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $26,498 | $0 | Implemented |