Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,577

matching recommendations
Reset
SIC 347 Metal Services, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0340 # 10 Y:1995 10 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $356 $570 Implemented
SF0061 # 01 Y:1995 01 1995 INSTALL OCCUPANCY SENSORS $1,935 $360 Not Implemented
SF0061 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $129 $170 Implemented
SF0061 # 03 Y:1995 03 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $347 $1,570 Not Implemented
SF0061 # 04 Y:1995 04 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $1,658 $2,208 Implemented
SF0061 # 05 Y:1995 05 1995 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $733 $1,300 Not Implemented
SF0061 # 06 Y:1995 06 1995 COVER OPEN TANKS $3,373 $1,560 Not Implemented
SF0061 # 07 Y:1995 07 1995 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $6,048 $2,955 Not Implemented
SF0061 # 08 Y:1995 08 1995 USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE $2,880 $25,300 Not Implemented
SF0061 # 09 Y:1995 09 1995 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $7,532 $1,288 Implemented
SF0061 # 10 Y:1995 10 1995 TREAT AND REUSE RINSE WATERS $10,340 $6,344 Not Implemented
MA0339 # 01 Y:1995 01 1995 BURN A LESS EXPENSIVE GRADE OF FUEL $4,128 $1,860 Implemented
MA0339 # 02 Y:1995 02 1995 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $1,027 $3,770 Implemented
MA0339 # 03 Y:1995 03 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $653 $0 Implemented
MA0339 # 04 Y:1995 04 1995 INSULATE BARE EQUIPMENT $504 $1,010 Not Implemented
MA0339 # 05 Y:1995 05 1995 RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER $57,939 $118,450 Not Implemented
MA0339 # 06 Y:1995 06 1995 RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER $23,990 $500 Not Implemented
MA0339 # 07 Y:1995 07 1995 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $824 $3,000 Not Implemented
AS0143 # 01 Y:1995 01 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,285 $17,600 Implemented
AS0143 # 02 Y:1995 02 1995 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $13,244 $60,000 Implemented
AS0143 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,764 $5,461 Implemented
AS0143 # 04 Y:1995 04 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,544 $0 Implemented
AS0143 # 05 Y:1995 05 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,823 $500 Implemented
AS0143 # 06 Y:1995 06 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $349 $599 Implemented
AS0143 # 07 Y:1995 07 1995 INSULATE BARE EQUIPMENT $8,829 $10,900 Implemented