Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,577
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0293 # 08 Y:1994 | 08 | 1994 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $769 | $0 | Implemented |
MA0293 # 09 Y:1994 | 09 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $739 | $0 | Implemented |
MA0293 # 10 Y:1994 | 10 | 1994 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $300 | $961 | Not Implemented |
SD0066 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,693 | $507 | Implemented |
SD0066 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,934 | $0 | Implemented |
SD0066 # 03 Y:1993 | 03 | 1993 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $6,874 | $1,012 | Not Implemented |
SD0066 # 04 Y:1993 | 04 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,788 | $315 | Not Implemented |
SD0066 # 05 Y:1993 | 05 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $893 | $300 | Implemented |
SD0066 # 06 Y:1993 | 06 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,069 | $120 | Implemented |
SD0066 # 07 Y:1993 | 07 | 1993 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $2,751 | $3,889 | Implemented |
SD0066 # 08 Y:1993 | 08 | 1993 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,375 | $15,000 | Implemented |
SD0066 # 09 Y:1993 | 09 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,598 | $0 | Implemented |
SD0066 # 10 Y:1993 | 10 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $51 | $180 | Implemented |
SD0066 # 11 Y:1993 | 11 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,691 | $1,140 | Implemented |
SD0066 # 12 Y:1993 | 12 | 1993 | INSTALL SET-BACK TIMERS | $376 | $600 | Implemented |
SD0066 # 13 Y:1993 | 13 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $369 | $0 | Implemented |
SD0066 # 14 Y:1993 | 14 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,774 | $916 | Implemented |
SD0066 # 15 Y:1993 | 15 | 1993 | INSTALL SET-BACK TIMERS | $328 | $25 | Implemented |
SD0066 # 16 Y:1993 | 16 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $1,166 | $300 | Implemented |
KU0411 # 01 Y:1993 | 01 | 1993 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $57,570 | $375,000 | Not Implemented |
KU0411 # 02 Y:1993 | 02 | 1993 | COVER OPEN TANKS | $17,260 | $11,104 | Implemented |
KU0411 # 03 Y:1993 | 03 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,681 | $35,000 | Not Implemented |
KU0411 # 04 Y:1993 | 04 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,229 | $710 | Implemented |
KU0411 # 05 Y:1993 | 05 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $294 | $171 | Implemented |
KU0411 # 06 Y:1993 | 06 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $976 | $1,200 | Implemented |