Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,577
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0369 # 04 Y:1992 | 04 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $946 | $0 | Implemented |
AM0135 # 01 Y:1991 | 01 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,330 | $6,532 | Implemented |
AM0135 # 02 Y:1991 | 02 | 1991 | INSULATE BARE EQUIPMENT | $2,190 | $100 | Implemented |
AM0135 # 03 Y:1991 | 03 | 1991 | INCREASE AMOUNT OF CONDENSATE RETURNED | $870 | $715 | Implemented |
AM0135 # 04 Y:1991 | 04 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $840 | $1,009 | Implemented |
AM0135 # 05 Y:1991 | 05 | 1991 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $630 | $340 | Implemented |
AM0135 # 06 Y:1991 | 06 | 1991 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $440 | $315 | Implemented |
AM0135 # 07 Y:1991 | 07 | 1991 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $320 | $0 | Implemented |
AM0135 # 08 Y:1991 | 08 | 1991 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $165 | $0 | Implemented |
AM0135 # 09 Y:1991 | 09 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $120 | $75 | Implemented |
AM0128 # 01 Y:1991 | 01 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,350 | $7,500 | Not Implemented |
AM0128 # 02 Y:1991 | 02 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $436 | $3,520 | Not Implemented |
AM0128 # 03 Y:1991 | 03 | 1991 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,970 | $0 | Not Implemented |
AM0128 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $920 | $940 | Not Implemented |
AM0128 # 05 Y:1991 | 05 | 1991 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $620 | $250 | Not Implemented |
AM0128 # 06 Y:1991 | 06 | 1991 | IMPROVE LUBRICATION PRACTICES | $410 | $0 | Not Implemented |
AM0128 # 07 Y:1991 | 07 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $530 | $285 | Not Implemented |
AM0128 # 08 Y:1991 | 08 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $215 | $130 | Not Implemented |
AM0128 # 09 Y:1991 | 09 | 1991 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $200 | $0 | Not Implemented |
AM0128 # 10 Y:1991 | 10 | 1991 | INSTALL SET-BACK TIMERS | $160 | $135 | Not Implemented |
AM0128 # 11 Y:1991 | 11 | 1991 | TURN OFF EQUIPMENT WHEN NOT IN USE | $130 | $90 | Not Implemented |
CO0217 # 01 Y:1991 | 01 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,147 | $1,550 | Implemented |
CO0217 # 02 Y:1991 | 02 | 1991 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,560 | $2,500 | Implemented |
CO0217 # 03 Y:1991 | 03 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,180 | $1,000 | Implemented |
CO0217 # 04 Y:1991 | 04 | 1991 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $1,160 | $1,150 | Implemented |