Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
88
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0375 # 07 Y:1996 | 07 | 1996 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $310 | $1,888 | Not Implemented |
MA0375 # 05 Y:1996 | 05 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $444 | $290 | Implemented |
MA0375 # 03 Y:1996 | 03 | 1996 | USE SYNTHETIC LUBRICANT | $329 | $0 | Not Implemented |
MA0375 # 08 Y:1996 | 08 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,823 | $47,265 | Not Implemented |
MA0375 # 06 Y:1996 | 06 | 1996 | INSTALL / REPAIR INSULATION ON STEAM LINES | $683 | $1,590 | Not Implemented |
MA0375 # 01 Y:1996 | 01 | 1996 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $7,468 | $4,677 | Not Implemented |
MA0375 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $456 | $157 | Implemented |
MA0375 # 11 Y:1996 | 11 | 1996 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $10,877 | $31,500 | Not Implemented |
MA0375 # 12 Y:1996 | 12 | 1996 | RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE | $28,830 | $97,000 | Not Implemented |
MA0375 # 10 Y:1996 | 10 | 1996 | IMPLEMENT A MAINTENANCE PROGRAM TO KEEP RACKS AND TANKS FREE OF RUST, CRACKS, OR CORROSION | $1,125 | $400 | Not Implemented |
MA0375 # 09 Y:1996 | 09 | 1996 | USE MAGNETIC TECHNOLOGY TO TREAT WATER | $9,036 | $6,000 | Not Implemented |
MA0375 # 02 Y:1996 | 02 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $2,121 | $1,100 | Implemented |
MA0377 # 03 Y:1996 | 03 | 1996 | PAY UTILITY BILLS ON TIME | $3,363 | $0 | Implemented |
MA0377 # 05 Y:1996 | 05 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $434 | $174 | Not Implemented |
MA0377 # 04 Y:1996 | 04 | 1996 | INSULATE BARE EQUIPMENT | $1,650 | $1,220 | Not Implemented |
MA0377 # 02 Y:1996 | 02 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $6,407 | $3,770 | Not Implemented |
MA0377 # 01 Y:1996 | 01 | 1996 | TREAT AND REUSE RINSE WATERS | $70,000 | $198,000 | Not Implemented |
UM0065 # 03 Y:1996 | 03 | 1996 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $464 | $990 | Not Implemented |
UM0065 # 04 Y:1996 | 04 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $42,447 | $990 | Not Implemented |
UM0065 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $293 | $300 | Not Implemented |
UM0065 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,223 | $5,402 | Not Implemented |
UM0062 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,611 | $3,000 | Not Implemented |
UM0062 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $616 | $718 | Implemented |
UM0062 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,893 | $4,042 | Implemented |
UM0062 # 06 Y:1996 | 06 | 1996 | USE SYNTHETIC LUBRICANT | $1,533 | $658 | Implemented |