Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0130 # 07 Y:2014 | 07 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,890 | $100 | Implemented |
UA0130 # 01 Y:2014 | 01 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $15,715 | $35,154 | Not Implemented |
UA0130 # 05 Y:2014 | 05 | 2014 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $6,867 | $4,120 | Not Implemented |
UA0130 # 02 Y:2014 | 02 | 2014 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $11,506 | $6,410 | Not Implemented |
UA0130 # 03 Y:2014 | 03 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $2,774 | $200 | Implemented |
UA0130 # 04 Y:2014 | 04 | 2014 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,266 | $0 | Implemented |
UA0130 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,986 | $2,522 | Not Implemented |
UD0913 # 04 Y:2014 | 04 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,643 | $8,500 | Not Implemented |
UD0913 # 08 Y:2014 | 08 | 2014 | COVER OPEN TANKS | $3,270 | $6,780 | Implemented |
UD0913 # 06 Y:2014 | 06 | 2014 | REPLACE BOILER | $19,697 | $163,500 | Not Implemented |
UD0913 # 05 Y:2014 | 05 | 2014 | ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA | $1,623 | $7,000 | Not Implemented |
UD0913 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $615 | $570 | Implemented |
UD0913 # 03 Y:2014 | 03 | 2014 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $511 | $1,275 | Implemented |
UD0913 # 01 Y:2014 | 01 | 2014 | UPGRADE CONVEYORS | $528 | $255 | Not Implemented |
UD0913 # 12 Y:2014 | 12 | 2014 | TREAT AND REUSE RINSE WATERS | $15,837 | $10,000 | Not Implemented |
UD0913 # 07 Y:2014 | 07 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,485 | $5,000 | Not Implemented |
UD0913 # 09 Y:2014 | 09 | 2014 | INSTALL AUTOMATIC STACK DAMPER | $2,665 | $0 | Implemented |
UD0913 # 10 Y:2014 | 10 | 2014 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $414,555 | $27,000 | Not Implemented |
UD0913 # 11 Y:2014 | 11 | 2014 | USE DECANTING, FLOTATION TO REMOVE CONTAMINANTS | $27,921 | $55,000 | Not Implemented |
MA0735 # 05 Y:2014 | 05 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,377 | $4,200 | Implemented |
MA0735 # 04 Y:2014 | 04 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,027 | $3,000 | Implemented |
MA0735 # 03 Y:2014 | 03 | 2014 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,084 | $500 | Implemented |
MA0735 # 02 Y:2014 | 02 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,745 | $3,519 | Implemented |
MA0735 # 01 Y:2014 | 01 | 2014 | OPTIMIZE PLANT POWER FACTOR | $23,815 | $17,955 | Not Implemented |
IP0026 # 06 Y:2014 | 06 | 2014 | INSULATE BARE EQUIPMENT | $221 | $286 | Not Implemented |