Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
502
matching recommendationsSIC | 3479 | Metal Coating And Allied Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0158 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,200 | $960 | Implemented |
AM0158 # 07 Y:1992 | 07 | 1992 | REPAIR AND ELIMINATE STEAM LEAKS | $3,780 | $870 | Implemented |
AM0158 # 08 Y:1992 | 08 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,190 | $1,150 | Implemented |
AM0158 # 10 Y:1992 | 10 | 1992 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,600 | $170 | Implemented |
AM0158 # 11 Y:1992 | 11 | 1992 | PAY UTILITY BILLS ON TIME | $1,213 | $0 | Implemented |
AM0158 # 12 Y:1992 | 12 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $425 | $0 | Implemented |
UD0369 # 02 Y:1992 | 02 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,020 | $0 | Implemented |
UD0369 # 03 Y:1992 | 03 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,504 | $0 | Implemented |
UD0369 # 04 Y:1992 | 04 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $850 | $0 | Implemented |
UD0369 # 05 Y:1992 | 05 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,413 | $300 | Implemented |
UD0369 # 07 Y:1992 | 07 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,842 | $1,800 | Implemented |
RU0114 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $826 | $0 | Implemented |
RU0114 # 02 Y:1991 | 02 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $261 | $214 | Implemented |
RU0114 # 03 Y:1991 | 03 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,104 | $2,150 | Implemented |
RU0114 # 04 Y:1991 | 04 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $858 | $700 | Implemented |
RU0114 # 05 Y:1991 | 05 | 1991 | IMPROVE LUBRICATION PRACTICES | $2,850 | $800 | Implemented |
RU0114 # 06 Y:1991 | 06 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,509 | $500 | Implemented |
RU0114 # 07 Y:1991 | 07 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $52,380 | $15,000 | Implemented |
RU0114 # 08 Y:1991 | 08 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,442 | $9,609 | Implemented |
AM0109 # 01 Y:1991 | 01 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,730 | $400 | Implemented |
AM0109 # 02 Y:1991 | 02 | 1991 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $700 | $156 | Implemented |
AM0109 # 03 Y:1991 | 03 | 1991 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $550 | $0 | Implemented |
AM0109 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $490 | $294 | Implemented |
AM0109 # 05 Y:1991 | 05 | 1991 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $304 | $0 | Implemented |
AM0109 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32 | $17 | Implemented |