Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,112
matching recommendationsSIC | 3479 | Metal Coating And Allied Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0459 # 03 Y:2000 | 03 | 2000 | OPTIMIZE PLANT POWER FACTOR | $6,420 | $15,880 | Implemented |
CO0459 # 04 Y:2000 | 04 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,670 | $1,130 | Not Implemented |
CO0459 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,650 | $2,070 | Implemented |
CO0459 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $440 | $560 | Not Implemented |
CO0459 # 07 Y:2000 | 07 | 2000 | INSULATE BARE EQUIPMENT | $350 | $80 | Not Implemented |
CO0459 # 08 Y:2000 | 08 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,070 | $9,130 | Not Implemented |
CO0459 # 09 Y:2000 | 09 | 2000 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $2,980 | $0 | Not Implemented |
CO0459 # 10 Y:2000 | 10 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $600 | $0 | Implemented |
DS0154 # 01 Y:2000 | 01 | 2000 | INSULATE BARE EQUIPMENT | $1,239 | $864 | Implemented |
DS0154 # 02 Y:2000 | 02 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,609 | $10,510 | Not Implemented |
DS0154 # 03 Y:2000 | 03 | 2000 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $2,737 | $8,160 | Not Implemented |
DS0154 # 04 Y:2000 | 04 | 2000 | RECYCLE CLEANING SOLVENT AND REUSE | $18,740 | $17,676 | Implemented |
DS0154 # 05 Y:2000 | 05 | 2000 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $3,521 | $1,336 | Implemented |
DS0154 # 06 Y:2000 | 06 | 2000 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $4,884 | $0 | Implemented |
SD0230 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,090 | $4,048 | Implemented |
SD0230 # 02 Y:1999 | 02 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,483 | $6,030 | Not Implemented |
SD0230 # 03 Y:1999 | 03 | 1999 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $257,414 | $480,000 | Not Implemented |
SD0230 # 04 Y:1999 | 04 | 1999 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $1,099,432 | $1,975,633 | Not Implemented |
SD0230 # 05 Y:1999 | 05 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $83,680 | $0 | Implemented |
SD0230 # 06 Y:1999 | 06 | 1999 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $39,860 | $16,000 | Not Implemented |
SD0230 # 07 Y:1999 | 07 | 1999 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $27,200 | $0 | Implemented |
SD0230 # 08 Y:1999 | 08 | 1999 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $0 | $2,410 | Implemented |
MA0441 # 01 Y:1999 | 01 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $21,168 | $5,704 | Implemented |
MA0441 # 02 Y:1999 | 02 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $43,200 | $3,000 | Implemented |
MA0441 # 03 Y:1999 | 03 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $15,964 | $40,000 | Not Implemented |