Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
33
matching recommendationsSIC | 348 | Ordnance And Accessories, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0441 # 01 Y:2017 | 01 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $174,581 | $25,494 | Not Implemented |
AS0441 # 02 Y:2017 | 02 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $10,783 | $37,000 | Implemented |
AS0441 # 03 Y:2017 | 03 | 2017 | USE SOLAR HEAT TO HEAT WATER | $1,380 | $1,005 | Not Implemented |
AS0436 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $106,561 | $115,692 | Not Implemented |
AS0436 # 03 Y:2017 | 03 | 2017 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $887 | $1,113 | Not Implemented |
AS0436 # 02 Y:2017 | 02 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $8,511 | $4,200 | Not Implemented |
AS0436 # 05 Y:2017 | 05 | 2017 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $5,490 | $12,200 | Not Implemented |
AS0436 # 01 Y:2017 | 01 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,161 | $100 | Not Implemented |
AS0415 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $928 | $3,000 | Not Implemented |
AS0415 # 01 Y:2006 | 01 | 2006 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $19,739 | $5,500 | Implemented |
AS0415 # 02 Y:2006 | 02 | 2006 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,463 | $24,000 | Not Implemented |
AS0415 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $810 | $12,174 | Not Implemented |
AS0415 # 06 Y:2006 | 06 | 2006 | USE SOLAR HEAT TO HEAT WATER | $132 | $2,800 | Not Implemented |
AS0415 # 03 Y:2006 | 03 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,372 | $1,000 | Implemented |
AS0288 # 05 Y:2000 | 05 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $15,129 | $11,400 | Implemented |
AS0288 # 10 Y:2000 | 10 | 2000 | IMPROVE SPACE COMFORT CONDITIONING | $4,649 | $12,600 | Not Implemented |
AS0288 # 09 Y:2000 | 09 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,700 | $60 | Not Implemented |
AS0288 # 08 Y:2000 | 08 | 2000 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $668 | $120 | Not Implemented |
AS0288 # 07 Y:2000 | 07 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,959 | $0 | Not Implemented |
AS0288 # 06 Y:2000 | 06 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,100 | $11,396 | Not Implemented |
AS0288 # 04 Y:2000 | 04 | 2000 | INSTALL OCCUPANCY SENSORS | $488 | $1,275 | Not Implemented |
AS0288 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,416 | $3,589 | Implemented |
AS0288 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $468 | $1,130 | Implemented |
AS0288 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,163 | $2,397 | Implemented |
AS0287 # 05 Y:2000 | 05 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $572 | $2,394 | Not Implemented |