Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,321
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0245 # 04 Y:1992 | 04 | 1992 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,090 | $1,720 | Implemented |
CO0245 # 05 Y:1992 | 05 | 1992 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $750 | $750 | Implemented |
CO0245 # 06 Y:1992 | 06 | 1992 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $220 | $250 | Implemented |
CO0245 # 07 Y:1992 | 07 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,680 | $4,010 | Implemented |
CO0245 # 08 Y:1992 | 08 | 1992 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $770 | $3,100 | Implemented |
CO0241 # 01 Y:1992 | 01 | 1992 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $3,250 | $5 | Implemented |
CO0241 # 02 Y:1992 | 02 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,920 | $3,500 | Implemented |
CO0241 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $530 | $200 | Implemented |
CO0241 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $370 | $110 | Implemented |
CO0241 # 05 Y:1992 | 05 | 1992 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $460 | $250 | Implemented |
CO0241 # 06 Y:1992 | 06 | 1992 | INSULATE BARE EQUIPMENT | $340 | $450 | Implemented |
CO0241 # 07 Y:1992 | 07 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $240 | $1,110 | Implemented |
MO0054 # 07 Y:1992 | 07 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $192 | $620 | Implemented |
WI0142 # 01 Y:1992 | 01 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,830 | $314 | Implemented |
WI0142 # 02 Y:1992 | 02 | 1992 | INSTALL SET-BACK TIMERS | $1,233 | $800 | Implemented |
WI0142 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $249 | $244 | Implemented |
WI0142 # 06 Y:1992 | 06 | 1992 | INSTALL STORM WINDOWS AND DOORS | $1,208 | $4,293 | Implemented |
WI0142 # 08 Y:1992 | 08 | 1992 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $601 | $525 | Implemented |
WI0142 # 09 Y:1992 | 09 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $498 | $0 | Implemented |
WI0142 # 10 Y:1992 | 10 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $270 | $400 | Implemented |
MO0048 # 04 Y:1992 | 04 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,183 | $292 | Implemented |
UF0013 # 01 Y:1991 | 01 | 1991 | OPTIMIZE PLANT POWER FACTOR | $27,648 | $34,850 | Implemented |
UF0013 # 02 Y:1991 | 02 | 1991 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $18,637 | $34,000 | Implemented |
UF0013 # 03 Y:1991 | 03 | 1991 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,117 | $0 | Implemented |
UF0013 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,964 | $0 | Implemented |