Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,115
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0119 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $930 | $0 | Implemented |
SU0119 # 03 Y:2001 | 03 | 2001 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $5,956 | $4,900 | Implemented |
SU0119 # 04 Y:2001 | 04 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,095 | $727 | Implemented |
SU0119 # 05 Y:2001 | 05 | 2001 | INSULATE BARE EQUIPMENT | $30,661 | $208,950 | Not Implemented |
SU0119 # 06 Y:2001 | 06 | 2001 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $46,417 | $15,500 | Not Implemented |
SU0119 # 07 Y:2001 | 07 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $2,456 | $0 | Implemented |
WI0406 # 01 Y:2001 | 01 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,841 | $0 | Implemented |
WI0406 # 02 Y:2001 | 02 | 2001 | OPTIMIZE PLANT POWER FACTOR | $7,981 | $14,550 | Not Implemented |
WI0406 # 03 Y:2001 | 03 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $3,632 | $600 | Not Implemented |
WI0406 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $3,556 | $3,880 | Not Implemented |
WI0406 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,901 | $0 | Not Implemented |
WI0406 # 06 Y:2001 | 06 | 2001 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,063 | $0 | Not Implemented |
WI0406 # 07 Y:2001 | 07 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $392 | $556 | Not Implemented |
WV0227 # 01 Y:2001 | 01 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,919 | $750 | Implemented |
WV0227 # 02 Y:2001 | 02 | 2001 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,589 | $1,980 | Not Implemented |
WV0227 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $913 | $100 | Implemented |
WV0227 # 04 Y:2001 | 04 | 2001 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $704 | $50 | Not Implemented |
WV0227 # 05 Y:2001 | 05 | 2001 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $603 | $390 | Implemented |
WV0227 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $275 | $112 | Implemented |
WV0227 # 07 Y:2001 | 07 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $31,855 | $2,000 | Implemented |
WV0227 # 08 Y:2001 | 08 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,200 | $1,000 | Implemented |
WV0227 # 09 Y:2001 | 09 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,150 | $2,910 | Implemented |
WV0227 # 10 Y:2001 | 10 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,267 | $3,000 | Not Implemented |
WV0227 # 11 Y:2001 | 11 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,814 | $100 | Implemented |
WV0227 # 12 Y:2001 | 12 | 2001 | ADJUST PH FOR NEUTRALIZATION | $8,625 | $13,725 | Not Implemented |