Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,115
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0101 # 03 Y:2001 | 03 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $78,362 | $2,500 | Implemented |
LE0101 # 04 Y:2001 | 04 | 2001 | IMPROVE LUBRICATION PRACTICES | $3,752 | $800 | Implemented |
LE0101 # 05 Y:2001 | 05 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $89,879 | $0 | Implemented |
LE0101 # 06 Y:2001 | 06 | 2001 | CLOSE OFF UNNEEDED STEAM LINES | $3,984 | $2,000 | Implemented |
LE0101 # 07 Y:2001 | 07 | 2001 | USE OPTIMUM THICKNESS INSULATION | $5,167 | $2,000 | Implemented |
LL0101 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $646 | $854 | Not Implemented |
LL0101 # 02 Y:2001 | 02 | 2001 | OPTIMIZE PLANT POWER FACTOR | $478 | $1,200 | Not Implemented |
LL0101 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,840 | $6,234 | Not Implemented |
LL0101 # 04 Y:2001 | 04 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $153 | $268 | Implemented |
LL0101 # 05 Y:2001 | 05 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $248 | $424 | Implemented |
LL0101 # 06 Y:2001 | 06 | 2001 | REDUCE SCRAP PRODUCTION | $1,788 | $0 | Implemented |
OK0610 # 01 Y:2001 | 01 | 2001 | INSTALL SET-BACK TIMERS | $14,000 | $1,670 | Implemented |
OK0610 # 02 Y:2001 | 02 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,700 | $1,110 | Not Implemented |
OK0610 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,939 | $16,000 | Not Implemented |
OK0610 # 04 Y:2001 | 04 | 2001 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $2,420 | $1,235 | Not Implemented |
OK0610 # 05 Y:2001 | 05 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $312,000 | $150,000 | Not Implemented |
NC0206 # 01 Y:2001 | 01 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $373 | $100 | Not Implemented |
NC0206 # 02 Y:2001 | 02 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,202 | $2,000 | Not Implemented |
NC0206 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $589 | $270 | Implemented |
NC0206 # 04 Y:2001 | 04 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $204 | $525 | Implemented |
NC0206 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,083 | $32,849 | Not Implemented |
NC0206 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $307 | $65 | Not Implemented |
NC0206 # 07 Y:2001 | 07 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,568 | $0 | Not Implemented |
NC0206 # 08 Y:2001 | 08 | 2001 | REDESIGN PROCESS | $9,810 | $40,000 | Implemented |
NC0206 # 09 Y:2001 | 09 | 2001 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,200 | $2,500 | Not Implemented |