Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,226
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0283 # 12 Y:1997 | 12 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $256 | $400 | Not Implemented |
ND0283 # 13 Y:1997 | 13 | 1997 | CONSIDER INTERMEDIATE OR ECONOMY SIZE AUTOS / TRUCKS | $156 | $0 | Not Implemented |
ND0283 # 14 Y:1997 | 14 | 1997 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $68 | $48 | Not Implemented |
NC0115 # 01 Y:1997 | 01 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $21,668 | $17,363 | Implemented |
NC0115 # 02 Y:1997 | 02 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,149 | $320 | Implemented |
NC0115 # 03 Y:1997 | 03 | 1997 | REDUCE VENTILATION AIR | $6,190 | $2,765 | Not Implemented |
NC0115 # 04 Y:1997 | 04 | 1997 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,108 | $4,000 | Not Implemented |
NC0115 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $726 | $120 | Implemented |
NC0115 # 06 Y:1997 | 06 | 1997 | INSTALL / REPAIR INSULATION ON STEAM LINES | $848 | $299 | Implemented |
NC0115 # 07 Y:1997 | 07 | 1997 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $391 | $0 | Not Implemented |
NC0115 # 08 Y:1997 | 08 | 1997 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $2,191 | $2,000 | Not Implemented |
NC0115 # 09 Y:1997 | 09 | 1997 | IMPROVE SPACE COMFORT CONDITIONING | $5,760 | $9,150 | Not Implemented |
OR0295 # 01 Y:1997 | 01 | 1997 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $86,250 | $1,000 | Not Implemented |
OR0295 # 02 Y:1997 | 02 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $36,000 | $40,000 | Not Implemented |
OR0295 # 03 Y:1997 | 03 | 1997 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,830 | $890 | Not Implemented |
OR0295 # 04 Y:1997 | 04 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $940 | $500 | Not Implemented |
OR0295 # 05 Y:1997 | 05 | 1997 | BURN A LESS EXPENSIVE GRADE OF FUEL | $7,820 | $10,000 | Not Implemented |
OR0295 # 06 Y:1997 | 06 | 1997 | COVER OPEN TANKS | $1,160 | $1,360 | Not Implemented |
OR0295 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,116 | $6,360 | Implemented |
OR0295 # 08 Y:1997 | 08 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $775 | $2,723 | Implemented |
ME0225 # 01 Y:1997 | 01 | 1997 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $17,807 | $31,600 | n/a |
ME0225 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,680 | $31,213 | n/a |
ME0225 # 03 Y:1997 | 03 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,962 | $0 | n/a |
ME0225 # 04 Y:1997 | 04 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,294 | $1,660 | n/a |
ME0225 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,089 | $0 | n/a |