Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
106
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0532 # 07 Y:1999 | 07 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $12,150 | $11,640 | Not Implemented |
KU0532 # 08 Y:1999 | 08 | 1999 | RECYCLE CLEANING SOLVENT AND REUSE | $2,620 | $800 | Implemented |
KU0498 # 01 Y:1998 | 01 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,010 | $4,150 | Not Implemented |
KU0498 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,610 | $650 | Implemented |
KU0498 # 03 Y:1998 | 03 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $560 | $570 | Implemented |
KU0498 # 04 Y:1998 | 04 | 1998 | USE SYNTHETIC LUBRICANT | $360 | $980 | Not Implemented |
KU0498 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $340 | $630 | Implemented |
KU0498 # 06 Y:1998 | 06 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $320 | $0 | Implemented |
KU0498 # 07 Y:1998 | 07 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $250 | $970 | Not Implemented |
KU0498 # 08 Y:1998 | 08 | 1998 | IMPLEMENT A MACHINE AND COOLANT SUMP CLEANING PROGRAM TO MINIMIZE COOLANT CONTAMINATION | $3,150 | $1,450 | Implemented |
KU0498 # 09 Y:1998 | 09 | 1998 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $2,930 | $3,000 | Not Implemented |
KU0498 # 10 Y:1998 | 10 | 1998 | CLEAR AND RENT EXISTING SPACE | $18,450 | $12,710 | Not Implemented |
KU0498 # 11 Y:1998 | 11 | 1998 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,960 | $730 | Implemented |
KU0498 # 12 Y:1998 | 12 | 1998 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $1,540 | $3,320 | Not Implemented |
OK0530 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,605 | $0 | n/a |
OK0530 # 02 Y:1997 | 02 | 1997 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $4,324 | $7,801 | n/a |
OK0530 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $594 | $548 | n/a |
OK0530 # 04 Y:1997 | 04 | 1997 | INSTALL SET-BACK TIMERS | $734 | $252 | n/a |
OK0530 # 05 Y:1997 | 05 | 1997 | USE BATCH FIRING WITH KILN "FURNITURE" SPECIFICALLY DESIGNED | $172 | $0 | n/a |
OK0530 # 06 Y:1997 | 06 | 1997 | MOVE PRODUCT USING MECHANICAL MEANS | $24,230 | $60,000 | n/a |
OK0530 # 07 Y:1997 | 07 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $548 | $1,040 | n/a |
OK0530 # 08 Y:1997 | 08 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $4,096 | $8,570 | n/a |
KU0465 # 01 Y:1996 | 01 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,543 | $80 | Implemented |
KU0465 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $4,536 | $15,210 | Implemented |
KU0465 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $2,887 | $1,300 | Implemented |