Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
340
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0821 # 01 Y:2012 | 01 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $43,921 | $24,480 | Not Implemented |
OK0795 # 09 Y:2010 | 09 | 2010 | INSTALL REPLACEMENT DOORS | $24,009 | $51,300 | Not Implemented |
OK0795 # 08 Y:2010 | 08 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,751 | $1,680 | Implemented |
OK0795 # 07 Y:2010 | 07 | 2010 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $896 | $5,000 | Implemented |
OK0795 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,260 | $159,982 | Not Implemented |
OK0795 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,244 | $11,715 | Not Implemented |
OK0795 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,677 | $1,100 | Implemented |
OK0795 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,567 | $513 | Not Implemented |
OK0795 # 02 Y:2010 | 02 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,321 | $4,015 | Not Implemented |
OK0795 # 01 Y:2010 | 01 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $41,350 | $68,550 | Not Implemented |
OK0782 # 08 Y:2009 | 08 | 2009 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $700 | $1,825 | Implemented |
OK0782 # 07 Y:2009 | 07 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,815 | $820 | Implemented |
OK0782 # 06 Y:2009 | 06 | 2009 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $804 | $4,800 | Not Implemented |
OK0782 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,300 | $11,120 | Not Implemented |
OK0782 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,005 | $7,542 | Not Implemented |
OK0782 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,733 | $0 | Implemented |
OK0782 # 02 Y:2009 | 02 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,732 | $3,742 | Not Implemented |
OK0782 # 01 Y:2009 | 01 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $852 | $354 | Implemented |
OK0775 # 10 Y:2009 | 10 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $3,858 | $2,925 | Implemented |
OK0775 # 09 Y:2009 | 09 | 2009 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $19,665 | $140,000 | Not Implemented |
OK0775 # 08 Y:2009 | 08 | 2009 | USE POWER DURING OFF-PEAK PERIODS | $30,940 | $0 | Not Implemented |
OK0775 # 07 Y:2009 | 07 | 2009 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $5,419 | $386 | Not Implemented |
OK0775 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,586 | $4,119 | Not Implemented |
OK0775 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,179 | $9,264 | Not Implemented |
OK0775 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,208 | $11,677 | Implemented |