Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
155
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0406 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,901 | $0 | Not Implemented |
WI0406 # 06 Y:2001 | 06 | 2001 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,063 | $0 | Not Implemented |
WI0406 # 07 Y:2001 | 07 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $392 | $556 | Not Implemented |
WI0362 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,236 | $1,860 | Not Implemented |
WI0362 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,550 | $740 | Not Implemented |
WI0362 # 03 Y:2000 | 03 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,619 | $16,000 | Not Implemented |
WI0362 # 04 Y:2000 | 04 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,741 | $14,500 | Not Implemented |
WI0362 # 05 Y:2000 | 05 | 2000 | TREAT AND REUSE RINSE WATERS | $3,598 | $6,375 | Implemented |
WI0362 # 06 Y:2000 | 06 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,130 | $2,150 | Not Implemented |
WI0362 # 07 Y:2000 | 07 | 2000 | REUSE / RECYCLE/ SELL RUBBER PRODUCTS | $1,562 | $0 | Not Implemented |
WI0334 # 01 Y:1998 | 01 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $182,000 | $200,000 | Not Implemented |
WI0334 # 02 Y:1998 | 02 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $3,225 | $500 | Implemented |
WI0334 # 03 Y:1998 | 03 | 1998 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $2,932 | $6,000 | Not Implemented |
WI0334 # 04 Y:1998 | 04 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,172 | $6,200 | n/a |
WI0334 # 05 Y:1998 | 05 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $1,094 | $800 | Implemented |
WI0334 # 06 Y:1998 | 06 | 1998 | MINIMIZE WATER USAGE | $400 | $1,875 | Not Implemented |
WI0334 # 07 Y:1998 | 07 | 1998 | COMBINE UTILITY METERS | $385 | $200 | Implemented |
WI0315 # 01 Y:1998 | 01 | 1998 | INSTALL EQUIPMENT TO MOVE PRODUCT | $82,125 | $50,000 | Not Implemented |
WI0315 # 02 Y:1998 | 02 | 1998 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $33,613 | $68,000 | Not Implemented |
WI0315 # 03 Y:1998 | 03 | 1998 | TREAT AND REUSE RINSE WATERS | $7,064 | $1,475 | Not Implemented |
WI0315 # 04 Y:1998 | 04 | 1998 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $4,722 | $14,000 | Not Implemented |
WI0315 # 05 Y:1998 | 05 | 1998 | COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES | $1,300 | $0 | Not Implemented |
WI0315 # 06 Y:1998 | 06 | 1998 | INSULATE BARE EQUIPMENT | $3,542 | $1,362 | Not Implemented |
WI0315 # 07 Y:1998 | 07 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,180 | $0 | Not Implemented |
WI0315 # 08 Y:1998 | 08 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,040 | $1,424 | Not Implemented |