Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
499
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0327 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,018 | $1,000 | Not Implemented |
BD0327 # 02 Y:2007 | 02 | 2007 | USE SYNTHETIC LUBRICANT | $4,257 | $600 | Not Implemented |
BD0327 # 03 Y:2007 | 03 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,520 | $600 | Not Implemented |
BD0327 # 04 Y:2007 | 04 | 2007 | INSTALL REPLACEMENT DOORS | $7,558 | $20,000 | Not Implemented |
BD0327 # 05 Y:2007 | 05 | 2007 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $15,124 | $6,800 | Not Implemented |
BD0327 # 06 Y:2007 | 06 | 2007 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $24,271 | $500 | Not Implemented |
BD0327 # 07 Y:2007 | 07 | 2007 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,763 | $0 | Not Implemented |
BD0327 # 08 Y:2007 | 08 | 2007 | USE PHOTOCELL CONTROLS | $36,411 | $10,000 | Not Implemented |
BD0327 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,900 | $9,230 | Not Implemented |
BD0327 # 10 Y:2007 | 10 | 2007 | INSTALL OCCUPANCY SENSORS | $1,702 | $1,200 | Not Implemented |
BD0327 # 11 Y:2007 | 11 | 2007 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $816 | $1,460 | Not Implemented |
IC0108 # 01 Y:2005 | 01 | 2005 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $85,726 | $22,992 | Not Implemented |
IC0108 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $500 | $300 | Not Implemented |
IC0108 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $425 | $0 | Not Implemented |
IC0108 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,400 | $0 | Not Implemented |
IC0108 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $77 | $0 | Not Implemented |
IC0108 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,427 | $0 | Not Implemented |
IC0092 # 01 Y:2004 | 01 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $4,234 | $30 | Not Implemented |
IC0092 # 02 Y:2004 | 02 | 2004 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,325 | $0 | Not Implemented |
IC0092 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $28,152 | $6,700 | Not Implemented |
IC0092 # 04 Y:2004 | 04 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $900 | $2,340 | Not Implemented |
IC0092 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,634 | $0 | Not Implemented |
IC0092 # 06 Y:2004 | 06 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,783 | $17,315 | Not Implemented |
IC0092 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $487 | $1,544 | Not Implemented |
IC0092 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $1,120 | $3,002 | Not Implemented |