Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

175

matching recommendations
Reset
SIC 349 Misc. Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ND0270 # 12 Y:1997 12 1997 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $109 $0 Not Implemented
ND0268 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $29,189 $25,928 n/a
ND0268 # 02 Y:1997 02 1997 OPTIMIZE PLANT POWER FACTOR $79,500 $98,000 n/a
ND0268 # 03 Y:1997 03 1997 $27,729 $25,000 n/a
ND0268 # 04 Y:1997 04 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,416 $3,000 n/a
ND0268 # 05 Y:1997 05 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,168 $3,240 n/a
ND0268 # 06 Y:1997 06 1997 RECOVER AND REUSE WASTE MATERIAL $4,500 $4,375 n/a
ND0268 # 07 Y:1997 07 1997 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $4,126 $6,156 n/a
ND0268 # 08 Y:1997 08 1997 INSTALL OCCUPANCY SENSORS $972 $6,400 n/a
ND0268 # 09 Y:1997 09 1997 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $823 $735 n/a
ND0268 # 10 Y:1997 10 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $495 $260 n/a
ND0268 # 11 Y:1997 11 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $296 $133 n/a
ND0268 # 12 Y:1997 12 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $300 $117 n/a
UM0072 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $800 $825 Implemented
UM0072 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,102 $8,496 Implemented
UM0072 # 03 Y:1996 03 1996 OPTIMIZE PLANT POWER FACTOR $4,048 $250 Not Implemented
UM0072 # 04 Y:1996 04 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $690 $1,200 Not Implemented
UM0072 # 05 Y:1996 05 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,823 $450 Implemented
UM0072 # 06 Y:1996 06 1996 $2,500 $80 Not Implemented
UM0068 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $994 $1,630 Implemented
UM0068 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,473 $18,075 Implemented
UM0068 # 03 Y:1996 03 1996 OPTIMIZE PLANT POWER FACTOR $5,202 $5,124 Implemented
UM0068 # 04 Y:1996 04 1996 USE SYNTHETIC LUBRICANT $659 $220 Not Implemented
UM0068 # 05 Y:1996 05 1996 USE RADIANT HEATER FOR SPOT HEATING $13,757 $55,000 Not Implemented
UM0068 # 06 Y:1996 06 1996 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $24,612 $3,100 Implemented