Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
276
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0014 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,545 | $250 | n/a |
LM0014 # 03 Y:2001 | 03 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $189 | $300 | n/a |
LM0014 # 04 Y:2001 | 04 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,883 | $263 | n/a |
LM0014 # 05 Y:2001 | 05 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $10,820 | $12,500 | n/a |
LM0014 # 06 Y:2001 | 06 | 2001 | INSTALL SENSORS TO DETECT DEFECTS | $22,000 | $2,800 | n/a |
LM0014 # 07 Y:2001 | 07 | 2001 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $8,000 | $1,000 | n/a |
LM0014 # 08 Y:2001 | 08 | 2001 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $131,040 | $36,250 | n/a |
LM0003 # 01 Y:2001 | 01 | 2001 | INSTALL SKYLIGHTS | $1,651 | $4,100 | Not Implemented |
LM0003 # 02 Y:2001 | 02 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,862 | $0 | Implemented |
LM0003 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,731 | $460 | Implemented |
LM0003 # 04 Y:2001 | 04 | 2001 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $2,824 | $0 | Implemented |
LM0003 # 05 Y:2001 | 05 | 2001 | MAINTAIN MACHINES TO REDUCE LEAKS | $750 | $350 | Implemented |
LM0003 # 06 Y:2001 | 06 | 2001 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $7,268 | $1,500 | Not Implemented |
LM0002 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,192 | $3,285 | Not Implemented |
LM0002 # 02 Y:2001 | 02 | 2001 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $1,259 | $3,158 | Not Implemented |
LM0002 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,253 | $250 | Implemented |
LM0002 # 04 Y:2001 | 04 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $508 | $0 | Implemented |
LM0002 # 05 Y:2001 | 05 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,282 | $12,475 | Not Implemented |
LM0002 # 06 Y:2001 | 06 | 2001 | USE ULTRASONIC CLEANING | $100,100 | $90,000 | Not Implemented |
LM0002 # 07 Y:2001 | 07 | 2001 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $128,500 | $0 | Implemented |
NV0140 # 01 Y:1999 | 01 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $110 | $52 | Not Implemented |
NV0140 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,840 | $800 | Implemented |
NV0140 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,509 | $4,692 | Implemented |
NV0140 # 04 Y:1999 | 04 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $556 | $1,360 | Not Implemented |
NV0140 # 05 Y:1999 | 05 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,041 | $0 | Not Implemented |