IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

213

matching recommendations
Reset
SIC 349 Misc. Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0088 # 06 Y:1996 06 1996 RECOVER WASTE HEAT FROM EQUIPMENT $610 $747 Not Implemented
WV0088 # 07 Y:1996 07 1996 INSULATE BARE EQUIPMENT $2,734 $252 Implemented
WV0088 # 08 Y:1996 08 1996 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $240 $1,000 Not Implemented
WV0086 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,618 $2,400 Not Implemented
WV0086 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $917 $6,390 Not Implemented
WV0086 # 03 Y:1996 03 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $406 $1,920 Not Implemented
WV0086 # 04 Y:1996 04 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,328 $748 Not Implemented
WV0086 # 05 Y:1996 05 1996 USE SYNTHETIC LUBRICANT $1,774 $1,600 Not Implemented
WV0086 # 06 Y:1996 06 1996 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $569 $1,467 Not Implemented
WV0086 # 07 Y:1996 07 1996 RECOVER WASTE HEAT FROM EQUIPMENT $303 $523 Not Implemented
WV0086 # 08 Y:1996 08 1996 ELIMINATE PRACTICE OF MIXING WASTE STREAMS $8,594 $5,400 Implemented
MS0051 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,762 $4,217 Implemented
MS0051 # 02 Y:1996 02 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $10,574 $39,728 Not Implemented
MS0051 # 03 Y:1996 03 1996 USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY $1,724 $7,665 Not Implemented
MS0051 # 04 Y:1996 04 1996 USE RE-USABLE FILTERS $900 $1,500 Not Implemented
MS0051 # 05 Y:1996 05 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $6,048 $20,000 Not Implemented
NC0077 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,351 $2,860 Not Implemented
NC0077 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $132 $840 Not Implemented
NC0077 # 03 Y:1996 03 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $278 $210 Implemented
NC0077 # 04 Y:1996 04 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $544 $160 Not Implemented
NC0077 # 05 Y:1996 05 1996 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $775 $0 Implemented
NC0077 # 06 Y:1996 06 1996 INSULATE BARE EQUIPMENT $306 $100 Not Implemented
NC0077 # 07 Y:1996 07 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,818 $5,000 Not Implemented
NC0077 # 08 Y:1996 08 1996 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $9,850 $1,800 Not Implemented
WV0077 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,444 $5,648 Implemented